<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-12T02:50:37Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/5ngx4jz7fg.1" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/5ngx4jz7fg.1</identifier>
                <datestamp>2025-07-11T09:24:07Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>li, runliu</dc:creator>
    <dc:title>Data Repository: An aptasensor for specific quantification of the signaling protein Amuc_1100 from Akkermansia muciniphila MucT</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>The combination of rGO-FETs (reduced Graphene Oxide-Field Effect Transistor) and DNA oligonucleotide aptamers has proved to be a promising technical method to detect analytes with high sensitivity and specificity. Targeting the Amuc_1100 protein, we demonstrate the application and ability of the aptamer/FET combination to detect Akkermansia muciniphila, an intestinal symbiont that improves host metabolism. Amuc_1100, a protein highly expressed on the bacterial outer membrane that signals to Toll-like receptor 2 and, has been shown to partially replicate these beneficial effects. By developing, characterizing, and demonstrating the suitability of SELEX based anti-AMUC_1100 aptamer libraries for the construction of functional rGO-FET sensors for specific and sensitive Amuc_1100 quantification, we provide evidence that the evolution of focused polyclonal aptamer libraries for related targets can be used as a straightforward strategy. Revolution and innovation in sensing technology will undoubtedly further improve the diagnostic and monitoring process in biomedical technlogy.</dc:description>
    <dc:subject>Field Effect Transistor</dc:subject>
    <dc:subject>Aptamer</dc:subject>
    <dc:subject>Microorganism</dc:subject>
    <dc:contributor>Kissmann, Ann-Kathrin</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/5ngx4jz7fg.1</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/5ngx4jz7fg.1</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/5ngx4jz7fg</dc:relation>
    <dc:date>2025-07-11T09:24:07Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
