<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-14T16:06:07Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/bcb9329f6d.1" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/bcb9329f6d.1</identifier>
                <datestamp>2025-01-27T08:14:39Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>Theart, Rensu</dc:creator>
    <dc:title>Photoplethysmography Device Data: Hardware and Participant Study Insights</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>This dataset accompanies the study &quot;Investigating the Design of a Photoplethysmography Device for Clinical Applications&quot; conducted by Anneri Appel (Aspeling) and Dr. Rensu P. Theart. It includes raw and processed data collected from 110 participants (participant 056 excluded due to a measurement error) and is intended to support reproducibility, further research, and development in photoplethysmography (PPG) device design and performance evaluation.

Structure of the Dataset:

1. Data Folder:  
   This folder contains PPG data recorded for each participant (except 056) using both green-LED and red-LED devices. Each participant has 8 text files named using the following convention:  
   ONSM_{GREEN/RED}_{data/time}_{IR/RG}_{participant number}.txt  
   - ONSM refers to the Onsemi photodiode used to capture the data.  
   - {GREEN/RED} indicates whether the data was captured using the green-LED or red-LED PPG device.  
   - {data/time} specifies whether the file contains ADC data (range: 0–65536) or timestamps (in milliseconds).  
   - {IR/RG} indicates the LED type used (infrared or red/green).  
   - {participant number} identifies the participant (001–110, excluding 056).  

   Data and timestamp files are paired, such that timestamps for ONSM_GREEN_data_IR_1.txt are located in ONSM_GREEN_time_IR_1.txt.

2. Participants Folder:  
   This folder contains a metadata file for each participant (001–110, excluding 056) with the following fields:  
   - No: Participant number.  
   - Age: Age in years.  
   - Sex: Biological sex (M/F).  
   - BMI: Body Mass Index classification (Normal, Underweight, Overweight).  
   - MST: Monk Skin Tone scale (1–10, where 10 indicates the darkest skin tone).  
   - CVH: Presence of known cardiovascular health problems.  
   - Blood Pressure: Blood pressure readings (mmHg).  
   - Seconds, SpO2, BPM: Time-stamped blood oxygen saturation (percent) and heart rate (beats per minute).  

Key Features and Applications:

This dataset is relevant for researchers and developers working on:  
1. PPG Device Design and Optimization: Includes raw hardware configuration data such as light source wavelength, brightness, photodetector lens shape, and sensor-to-skin contact pressure.  
2. Participant Study Analysis: Provides cardiovascular metrics collected from a demographically diverse group, facilitating investigations into the effects of factors like skin tone (MST) and BMI on PPG signal quality.  
3. Neural Network Training: Contains data that can be used to train and validate neural networks for applications like blood pressure estimation.

Intended Use:
The dataset is designed to support reproducibility of findings from the study and encourage further research in PPG-based vital sign monitoring, particularly in diverse clinical and demographic settings.

For more context and details about the methodology, please refer to the associated publication.</dc:description>
    <dc:subject>Bioengineering</dc:subject>
    <dc:subject>Sensor</dc:subject>
    <dc:contributor>Appel, Anneri</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/bcb9329f6d.1</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/bcb9329f6d.1</dc:identifier>
    <dc:rights>Attribution-NonCommercial 3.0 Unported</dc:rights>
    <dc:rights>https://creativecommons.org/licenses/by-nc/3.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/bcb9329f6d</dc:relation>
    <dc:date>2025-01-27T08:14:39Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>