<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-16T00:06:52Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/cb887gkmxw.2" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/cb887gkmxw.2</identifier>
                <datestamp>2024-09-16T18:24:19Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>Mustafa, Hamza</dc:creator>
    <dc:title>SoC Estimation on Li-ion Batteries: A New EIS-based Dataset for data-driven applications</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>On 11 brand new cylindrical rechargeable Lithium Iron Phosphate batteries, Electrochemical Impedance Spectroscopy (EIS) were measured at SoC 100%, 95%, 90%, 85%, 80%, 75%, 70%, 65%, 60%, 55%, 50%, 45%, 35%, 30%, 25%, 20%, 15%, 10%, 5%. All of these measures for each battery are repeated for two discharge cycles.  

Impedance frequencies[ 0.01, 0.02, 0.03, 0.05, 0.08, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 2, 3, 5, 8, 10, 11, 21, 31, 61, 81, 100, 110, 210, 310, 510, 810, 1000 ] Hz used for the all EIS spectrum.

The files are organized in directories. There are eleven directories one for each battery, from “ B01” to “ B11”. Each of these directories further contains two directories, “ EIS Measurement” and  “Capacity Measurement”. In the first one there are all the test directories, inside each test folder there are the corresponding test comma-separated values (csv) files with all the impedance spectroscopy measurements. In the second folder, on the same level as “ EIS Measurement” there is the battery capacity test also in a csv formatted file.
</dc:description>
    <dc:subject>Electrochemistry</dc:subject>
    <dc:subject>Spectroscopy</dc:subject>
    <dc:subject>Battery Charging</dc:subject>
    <dc:subject>Lithium Battery</dc:subject>
    <dc:subject>Impedance</dc:subject>
    <dc:subject>State-of-Charge</dc:subject>
    <dc:contributor>Bourelly, Carmine</dc:contributor>
    <dc:contributor>Vitelli, Michele</dc:contributor>
    <dc:contributor>Milano, Fillippo </dc:contributor>
    <dc:contributor>Molinara, Mario</dc:contributor>
    <dc:contributor>Ferrigno  , Luigi </dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/cb887gkmxw.2</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/cb887gkmxw.2</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/cb887gkmxw</dc:relation>
    <dc:date>2024-09-16T18:24:19Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
