<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-14T18:55:37Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/cjdt7jtsmr.1" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/cjdt7jtsmr.1</identifier>
                <datestamp>2020-02-29T21:29:48Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>Ren, Ming</dc:creator>
    <dc:title>Data for: Fault prediction of gas-insulated system with hypersensitive optical monitoring and spectral information</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>Data for Fig. 1. Phase-resolved scatterplots (φ, q), double-spectral scatterplots (Iband1, Iband2) for corona discharges occurring along the needle-plane gaps with different gap distances (d). (a)-(c): (φ, q); (d)-(f): (Iband1, Iband2);
Data for Fig. 2. Integral spectra of the corona discharge in SF6 (gap distance = 50 mm; gas pressure = 0.3 MPa; f = 15). A fiber-optic spectrometer (200-1150 nm), a collecting lens installed outside the quartz glass window of the test chamber, and a 19-core silica fiber were employed to measure the integral spectra of the discharges.
Data for Fig. 7. Light intensity stochastic distributions in a RGB 3-D coordinate system for the three types of defect.
Data for Fig. 11. Scatterplots of the DBSCAN clustering results for a double-sourced discharge (floating discharge and creeping discharge occur simultaneously with a discharge level of 320 pC). 
Data for Fig. 15. Results of clustering analysis on TSS data (Cluster 1 and Cluster 2) and the evolution paths of the two types of discharge (Corona discharge: 30 μJ→93 μJ; Floating discharge: 77 μJ→224 μJ).
</dc:description>
    <dc:subject>Diagnosis</dc:subject>
    <dc:subject>Spectral Method</dc:subject>
    <dc:subject>Sensing Principle</dc:subject>
    <dc:subject>Partial Discharge Diagnostics</dc:subject>
    <dc:contributor>Dong, Ming</dc:contributor>
    <dc:contributor>Xia, Changjie</dc:contributor>
    <dc:contributor>Zhang, Chongxing</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/cjdt7jtsmr.1</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/cjdt7jtsmr.1</dc:identifier>
    <dc:rights>Public Domain Dedication</dc:rights>
    <dc:rights>http://creativecommons.org/publicdomain/zero/1.0/</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/cjdt7jtsmr</dc:relation>
    <dc:date>2020-02-29T21:29:48Z</dc:date>
    <dc:date>2020-06-29T00:00:00Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
