<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-09T21:47:58Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/d9j2chwdz8.2" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/d9j2chwdz8.2</identifier>
                <datestamp>2020-04-25T19:45:32Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>Akmal, Jan Sher</dc:creator>
    <dc:title>Cumulative inaccuracies in implementation of additive manufacturing through medical imaging, 3D thresholding, and 3D modeling: A case study for an end-use implant</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>This data belongs to the original scientific article that is “Cumulative Inaccuracies in Implementation of Additive Manufacturing Through Medical Imaging, 3D Thresholding, and 3D Modeling: A Case Study for an End-Use Implant” by Jan Sher Akmal, Mika Salmi, Björn Hemming, Linus Teir, Anni Suomalainen, Mika Kortesniemi, Jouni Partanen, and Antti Lassila published with MDPI in Applied Sciences (Switzerland) Special Issue — 3D Printing of Bioactive Medical Device . It contains medical CT-images of a sus domesticus acquired using a Siemens Somatom Definition Edge CT system. 

Please cite the original scientific article if you use this data as follows:
Akmal, J.S.; Salmi, M.; Hemming, B.; Teir, L.; Suomalainen, A.; Kortesniemi, M.; Partanen, J.; Lassila, A. Cumulative Inaccuracies in Implementation of Additive Manufacturing Through Medical Imaging, 3D Thresholding, and 3D Modeling: A Case Study for an End-Use Implant. Appl. Sci. 2020, 10, 2968. https://doi.org/10.3390/app10082968</dc:description>
    <dc:subject>Engineering</dc:subject>
    <dc:subject>Radiology</dc:subject>
    <dc:subject>Uncertainty</dc:subject>
    <dc:subject>Computer-Aided Design</dc:subject>
    <dc:subject>Biomedical Engineering</dc:subject>
    <dc:subject>Mechanical Engineering</dc:subject>
    <dc:subject>Medical Imaging</dc:subject>
    <dc:subject>Computer-Aided Manufacturing</dc:subject>
    <dc:subject>3D Imaging</dc:subject>
    <dc:subject>Image Segmentation</dc:subject>
    <dc:subject>Manufacturing</dc:subject>
    <dc:subject>Error Analysis</dc:subject>
    <dc:subject>Computed Tomography</dc:subject>
    <dc:subject>Cranio-Maxillofacial Surgery</dc:subject>
    <dc:subject>Three Dimensional Printing</dc:subject>
    <dc:subject>Spatial 3D Modeling</dc:subject>
    <dc:subject>Accuracy Analysis</dc:subject>
    <dc:subject>Error Propagation</dc:subject>
    <dc:subject>Segmentation</dc:subject>
    <dc:subject>Uncertainty Analysis</dc:subject>
    <dc:subject>Implant</dc:subject>
    <dc:subject>Clinical Uncertainty</dc:subject>
    <dc:subject>Design for Additive Manufacture</dc:subject>
    <dc:contributor>Salmi, Mika</dc:contributor>
    <dc:contributor>Hemming, Björn</dc:contributor>
    <dc:contributor>Teir, Linus</dc:contributor>
    <dc:contributor>Suomalainen, Anni</dc:contributor>
    <dc:contributor>Kortesniemi, Mika</dc:contributor>
    <dc:contributor>Partanen, Jouni</dc:contributor>
    <dc:contributor>Lassila, Antti</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/d9j2chwdz8.2</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/d9j2chwdz8.2</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/d9j2chwdz8</dc:relation>
    <dc:date>2020-04-25T19:45:32Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
