<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-13T13:14:12Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/gnrpbkhsj3.3" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/gnrpbkhsj3.3</identifier>
                <datestamp>2025-02-21T16:02:12Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator id="https://orcid.org/0000-0003-1891-7637">Derkachova, Anastasiya</dc:creator>
    <dc:title>Refractive index of 4 glycols versus wavelength and temperature</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>The dataset consists of tables of refractive index values versus wavelength and temperature n(lambda, T) for 4 hygroscopic organic liquids. Each table corresponds to one liquid: (i) HEG – hexaethylene glycol, 96% abcr GmbH lot 1508060; (ii) PEG – pentaethylene glycol, 98.0%, Alfa Aesar lot 10207595 and pentaethylene glycol, 97.0%, abcr GmbH lot 1509179 (no differences in measurements were found) ; (iii) TPG – tripropylene glycol, ≥99%, Alfa Aesar lot H25W018; (iv) DPG – dipropylene glycol, mixture of isomers, 99%, Alfa Aesar lot 10201331. The measurements cover the range from 390 to 1070 nm in wavelength and from 1 to 45ºC in temperature. Each data point corresponds to a mean value of several measurements. Outlier measurement series were discarded. The accuracy of the refractive index measurement is estimated to be ±0.0003, while the accuracy of the wavelength measurement is ~1%, and the accuracy of the temperature measurement is ±0.5 K. The measurements were performed with a modified Abbe refractometer. The calibration was performed with water at each temperature from 5 to 45ºC and with ethylene glycol at 1ºC. The details of experimental setup and procedures can be found in [Jakubczyk et al., Chromatic dispersion and thermal coefficients of hygroscopic liquids: 5 glycols and glycerol, Scientific Data, (2023) 10:894, DOI: 10.1038/s41597-023-02819-3]. The SketchUp file (.skp, 2017 format) contains the corresponding 3D model, while the .mp4 file contains a walk-around video of the setup, generated from the model.</dc:description>
    <dc:subject>Optical Property of Condensed Matter</dc:subject>
    <dc:subject>Dispersion (Optics)</dc:subject>
    <dc:subject>Refractive Index</dc:subject>
    <dc:subject>Temperature Effect</dc:subject>
    <dc:subject>Chromatic Dispersion</dc:subject>
    <dc:contributor id="https://orcid.org/0000-0002-2144-3228">Jakubczyk, Daniel</dc:contributor>
    <dc:contributor id="https://orcid.org/0000-0003-2448-644X">Derkachov, Gennadiy</dc:contributor>
    <dc:contributor id="https://orcid.org/0000-0002-3535-7849">Nyandey, Kwasi</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/gnrpbkhsj3.3</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/gnrpbkhsj3.3</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/gnrpbkhsj3</dc:relation>
    <dc:date>2025-02-21T16:02:12Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
