<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-15T21:42:53Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/m7xnggdfjm.1" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/m7xnggdfjm.1</identifier>
                <datestamp>2025-12-05T00:28:56Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator id="https://orcid.org/0009-0008-0250-4145">Schmidt, Stefan</dc:creator>
    <dc:title>Dataset for Fluorescent Nuclear Track Detectors for out-of-field neutron dosimetry in proton therapy</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>This dataset was generated in: 
Schmidt, S., Muñoz, I. D., Yukihara, E. G., Vedelago, J. (2025). Fluorescent Nuclear Track Detectors for out-of-field neutron dosimetry in proton therapy. Submitted to Medical Physics.

Dataset overview: 
This dataset contains fluorescence (“fl”) and reflection (“re”) microscopy images of alumina-based Fluorescent Nuclear Track Detectors (FNTDs). These detectors were used to measure out-of-field neutron dose values in a clinical proton beam.

Experimental setup: 
   Phantom: RW3 and PMMA phantom
   - Dimensions: 30 cm × 30 cm × 30 cm
   - Target volume: 10 cm × 10 cm × 10 cm, located at 10 cm to 20 cm depth
   Detector placement
   - For RW3-I and PMMA-I, all three FNTDs were positioned 8.1 cm downstream of the phantom isocenter
   - For RW3-II and PMMA-II, all three FNTDs were positioned 14.1 cm downstream of the phantom isocenter
   - No lateral (x-direction) shift
   - The FNTDs were placed 1 cm to 2 cm above the isocenter level
   Irradiation context
   - Out-of-field neutron dosimetry in primary proton beams

Image acquisition:
Detector readout was conducted with a dedicated confocal laser scanning microscopy (FXR700RG).
Each detector was scanned at multiple x–y positions, resulting in 175 x–y image locations per FNTD. At each x–y location, a z-stack consisting of 11 images was recorded. For every image, two channels were acquired: 
- fl – fluorescence image (ionizing particle tracks)
- re – reflection image (surface and structural information)

The structure of each zip file is summarized below:
  Component                        Value
  ------------------------- -----------
  Number of detectors            3
  x–y images per detector    175
  z-stack slices per image      11 
  Channels per image             2
  Configuration file                 1
--------------------------------------
A total of 11,550 images per file (~ 5.5 GB unzipped)

File naming convention:
Each image name follows the structure
        FNTD_aa_ybb_xcc_zddee_f.png
where
        aa   = detector number (01, 02, ...)
        bb   = y index
        cc   = x index
        dd  = z slice index
        ee   = channel (&quot;fl&quot; or &quot;re&quot;)
        f     = detector index without leading zero (0, 1, ...)

Note 1: To properly visualize 16-bit images, it may be necessary to apply intensity scaling (e.g. using ImageJ/FIJI). If not, the images might appear black.
Note 2: For images with x indices of 1 or 2, the dominant signal is due to tracks from a Cm-244 source, which is used for inter-detector sensitivity correction. Therefore, out-of-field analysis is only conducted for images with different x indices. </dc:description>
    <dc:subject>Medical Physics</dc:subject>
    <dc:subject>Dosimetry</dc:subject>
    <dc:subject>Neutron Detector</dc:subject>
    <dc:subject>Solid State Nuclear Track Detector</dc:subject>
    <dc:contributor id="https://orcid.org/0000-0001-5510-9749">Vedelago, José</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/m7xnggdfjm.1</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/m7xnggdfjm.1</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/m7xnggdfjm</dc:relation>
    <dc:date>2025-12-05T00:28:56Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>