<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-13T18:20:57Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/r7rrf8wn99.3" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/r7rrf8wn99.3</identifier>
                <datestamp>2021-03-09T13:39:35Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>Gao, Nan</dc:creator>
    <dc:title>Particle Image Velocimetry (PIV) measurement data for backward facing step flows with and without periodic perturbations</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>Flow fields downstream of a backward-facing step with a Reynolds number (UH/\nu) of 9630 were measured using a 2D2C PIV system. Freestream velocity is U=5.7m/s, H=0.025m. Flow was also perturbed using a synthetic jet actuator deployed at the separation point with a range of perturbation frequencies (St= 0.04 to 0.39) and amplitudes (u_A/U= 0.3 to 0.9) .  A total of 2000 image pairs were acquired at a rate of 50 Hz for the unperturbed flow, 47 Hz for the flow perturbed at 70 Hz and 49 Hz for other perturbed flow.  In this data set, there are a total of 37 data files saved in Matlab2013 MAT format. Files with a name &apos;f(a)c(b)Vec1.mat&apos; have a size of 3280(spatial locations)*2000(number of snapshots)*2(two velocity components). Unit is m/s. Here in the file name, a=[0:1:9], 0:unperturbed flow, 1:perturbed at 10Hz,  2:20Hz,  3:30Hz,  4:40Hz,  5:50Hz,  6:60Hz,  7:70Hz,  7:70Hz,  8:80Hz,  9:90Hz; corresponding to	St=fH/U=[0  0.0439    0.0877    0.1316    0.1754    0.2193   0.2632    0.3070    0.3509    0.3947]; b=[1:1:4], corresponding to perturbation amplitude of u_A/U=[0.3 0.5 0.7 0.9]. The file &apos;X.mat&apos; and &apos;Y.mat&apos; is the stream-wise and vertical position respectively. Both files have a size of 3280 and normalized using step height, H.  More details about the experiment were described in Li, Z.Y., Guo, S., Bai, H.L. &amp; Gao, N. 2019 Combined flow and heat transfer measurements of backward-facing step flows under periodic perturbation. Int J Heat Mass Trans 130, 240–251, 10.1016/j.ijheatmasstransfer.2018.10.077. I am available at gaonan@hit.edu.cn, or a permanent email  gaonum@126.com</dc:description>
    <dc:subject>Fluid Mechanics</dc:subject>
    <dc:subject>Turbulence</dc:subject>
    <dc:subject>Particle Image Velocimetry</dc:subject>
    <dc:contributor>Li, Zhuoyue</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/r7rrf8wn99.3</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/r7rrf8wn99.3</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/r7rrf8wn99</dc:relation>
    <dc:date>2021-03-09T13:39:35Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
