<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-16T01:26:57Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/sy625fznsn.1" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/sy625fznsn.1</identifier>
                <datestamp>2026-05-29T12:19:52Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>Hayrullin, Aidar</dc:creator>
    <dc:title>Experimental study of heat transfer in an in-line tube bundle under reciprocating pulsating cross-flow: effects of Prandtl number and waveform asymmetry</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>This dataset contains operating parameters, similarity criteria, and measurement uncertainties for 180 pulsating-flow experimental regimes conducted on an 8×8 in-line tube bundle (D = 10 mm, S_L/D = S_T/D = 1.3) with water as the working fluid. Experiments cover the parameter ranges Re = 1200-3400, Pr = 3.5-5.0, A/D = 5-15, f = 0.18-0.45 Hz, and duty cycle psi = 0.2-0.5. The dataset includes the Nusselt number under pulsating flow (Nu_p), the heat transfer enhancement ratio (Nu_p/Nu_st), derived similarity parameters (Strouhal number, Fourier number, combined parameter (A/D)St), and expanded measurement uncertainties at the 95% confidence level evaluated in accordance with the GUM framework. Full description of the experimental methodology and data reduction procedure is provided in the associated manuscript.</dc:description>
    <dc:subject>Heat Transfer</dc:subject>
    <dc:subject>Thermal Engineering</dc:subject>
    <dc:subject>Heat Exchanger</dc:subject>
    <dc:subject>Heat Transfer Analysis</dc:subject>
    <dc:contributor id="https://orcid.org/0000-0001-6927-8949">Haibullina, Aigul</dc:contributor>
    <dc:contributor>Dyachuk, Julia</dc:contributor>
    <dc:contributor>Balzamov, Denis</dc:contributor>
    <dc:contributor id="https://orcid.org/0000-0002-9399-2824">Ilyin, Vladimir</dc:contributor>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/sy625fznsn.1</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/sy625fznsn.1</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/sy625fznsn</dc:relation>
    <dc:date>2026-05-29T12:19:52Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
