<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-15T17:10:06Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/xncfcdsyj7.1" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/xncfcdsyj7.1</identifier>
                <datestamp>2019-12-29T11:18:43Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>Ren, Ming</dc:creator>
    <dc:title>(Data alongside) Fault prediction of gas-insulated system with hypersensitive optical monitoring and spectral information</dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>Fig. 1. Phase-resolved scatterplots (φ, q), double-spectral scatterplots (Iband1, Iband2)
for corona discharges occurring along the needle-plane gaps with different gap distances (d). (a)-(c): (φ, q); (d)-(f): (Iband1, Iband2);
Fig. 2. Integral spectra of the corona discharge in SF6 (gap distance = 50 mm; gas pressure = 0.3 MPa; f = 15). A fiber-optic spectrometer (200-1150 nm), a collecting lens installed outside the quartz glass window of the test chamber, and a 19-core silica fiber were employed to measure the integral spectra of the discharges.
Fig. 7. Light intensity stochastic distributions in an RGB 3-D coordinate system for the three types of defect.
Fig. 11. Scatterplots of the DBSCAN clustering results for a double-sourced discharge (floating discharge and creeping discharge occur simultaneously with a discharge level of 320 pC). 
Fig. 15. Results of clustering analysis on TSS data (Cluster 1 and Cluster 2) and the evolution paths of the two types of discharge (Corona discharge: 30 μJ→93 μJ; Floating discharge: 77 μJ→224 μJ).

</dc:description>
    <dc:subject>Optical Information Processing</dc:subject>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/xncfcdsyj7.1</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/xncfcdsyj7.1</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/xncfcdsyj7</dc:relation>
    <dc:date>2019-12-29T11:18:43Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
