<?xml version="1.0" encoding="UTF-8" standalone="yes"?><?xml-stylesheet type="text/xsl" href="/oai-pmh-repository/static/oai2.xsl"?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
    <responseDate>2026-10-15T02:39:01Z</responseDate>
    <request verb="GetRecord" identifier="oai:data.mendeley.com/z2ssm2pswg.1" metadataPrefix="oai_dc">https://data.mendeley.com/oai</request>
    <GetRecord>
        <record>
            <header>
                <identifier>oai:data.mendeley.com/z2ssm2pswg.1</identifier>
                <datestamp>2024-09-11T06:40:38Z</datestamp>
            </header>
            <metadata><oai_dc:dc xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <dc:creator>lichun, Guo</dc:creator>
    <dc:title>Gas chromatography tandem mass spectrometry (GC-MS/MS) analysis of SCFAs </dc:title>
    <dc:publisher>Mendeley Data</dc:publisher>
    <dc:description>The caecal contents (50 mg) were homogenized for 1 min with 50 μL of phosphoric acid (15%, v,v) and ether (400 μL) containing isocaproic acid (125 μg/mL, 100 μL) as an internal standard. After centrifugation for 10 min (12,000 rpm/min, 4℃), the supernatant was collected, and the concentrations of SCFAs in the samples were determined by GC/MS, equipped with an Agilent HP-Innowax capillary column (30 m × 0.25 mm; ID, 0.25 μm) in a trace 1310 GC system. Helium was used as the carrier gas, with a flow rate of 1 mL/min. Injection was made in split mode at 10:1 with an injection volume of 1 μL and injector temperature of 250℃. The temperature of the ion source and GC/MS interface were 230°C and 250°C, respectively. The oven temperature was programmed to proceed from an initial temperature of 90°C to 120℃ at 10℃/min, and then to 150℃ at 5℃/min, and ultimately to 250℃ at 25℃/min, where it was held for 2 min. The mass spectrometer was operated in the electron impact ionization mode and selective ion monitoring mode with a collision energy of 70 eV. 
A mixture of SCFA standards (MilliporeSigma) that included acetic acid, propionic acid, butyric acid, isobutyric acid, valeric acid, isovaleric acid, and caproic acid was used to prepare calibration curves at a concentration range of 0.02 to 500 μg/mL. The concentration of total SCFAs was calculated as the sum of the measured concentrations of the 7 SCFA standards. </dc:description>
    <dc:subject>Metabolite</dc:subject>
    <dc:subject>Metabonomics</dc:subject>
    <dc:type>Dataset</dc:type>
    <dc:identifier>doi:10.17632/z2ssm2pswg.1</dc:identifier>
    <dc:identifier>oai:data.mendeley.com/z2ssm2pswg.1</dc:identifier>
    <dc:rights>Creative Commons Attribution 4.0 International</dc:rights>
    <dc:rights>http://creativecommons.org/licenses/by/4.0</dc:rights>
    <dc:relation>https://data.mendeley.com/datasets/z2ssm2pswg</dc:relation>
    <dc:date>2024-09-11T06:40:38Z</dc:date>
</oai_dc:dc></metadata>
        </record>
    </GetRecord>
</OAI-PMH>
