Filter Results
6821 results
This file contains a prototype semi-structured interview questionnaire that was used for cross country synthesis on the subject of post-disaster reconstruction and resettlement
Data Types:
  • Dataset
  • Document
As a part of a research into new techniques for purifying recycled aluminium alloys, a novel electromagnetic apparatus had been developed for investigating in real-time the separation mechanisms of detrimental inclusions in aluminium alloy melts under alternating magnetic fields. The magnetic coil was designed based on the Helmholtz coil design. A viewing gap was designed for in-situ imaging studies using synchrotron X-rays. The gap was designed to maintain a uniform magnetic field in the central region where a sample is positioned. The current setup for the magnetic coil pair is able to produce a peak magnetic flux density of ~10 mT at a frequency of 25 kHz. A separate electrical resistance furnace, designed to concentrically fit within the magnetic coils, was used to control the heating (up to ~850°C) and cooling of the samples. After a series of systematic tests and commissioning, the apparatus was used in a number of in-situ and ex-situ experiments.
Data Types:
  • Tabular Data
  • Dataset
  • Document
This dataset contains the primary data used in: "Multi-epoch X-ray burst modelling: MCMC with large grids of 1D simulations", Johnston et al. (2020). In this work, we interpolated and sampled a grid of 3840 KEPLER burst models using Markov Chain Monte Carlo (MCMC) methods to produce posterior distributions for the system parameters of the "Clocked Burster", GS 1826-238. Provided here is the full burst model grid and the raw MCMC sample chains. More details on the files, and how to load them, are provided in README.md
Data Types:
  • Software/Code
  • Dataset
  • Text
  • File Set
Supplementary data supporting the manuscript updated with 4 donor results to replace the previous dataset from one donor
Data Types:
  • Dataset
  • Document
Dataset for the paper entitled "Real-time command strategies for microgrids based on the Contract Collaboration Problem". You are free to use the instances in the zip file, if you cite the following work: @article{Levorato2020, author = {Levorato, M. and Figueiredo, R. and Frota, Y. and Jouglet, A. and Savourey, D.}, journal = {To be published}, title = {{Real-time command strategies for microgrids based on the Contract Collaboration Problem}}, year = {2020} } Instances description ================================= 1) full_intances: the 3 microgrid instances used in the main experiments: - A_instance2_1NDU_Cons : the *Cons* microgrid instance, with only the consumer uncertain system; - A_instance2_1NDU_Prod : the *Prod* microgrid instance, with only the producer uncertain system; - A_instance2 : the *Prod\&Cons* microgrid instance, with both uncertain systems (producer and consumer). For each instance, there are 3 files, each one for a group of randomly generated scenarios: - _1000s_skewed-left.txt : left-skewed beta distribution with parameters $\alpha=5,\beta=2$; - _1000s_skewed-right.txt : right-skewed beta distribution with parameters $\alpha=2,\beta=5$; - _1000s_uniform.txt: uniform distribution. The randomly-generated scenario values are located in the end of each file. 2) toy_sensitivity: reduces microgrid instances used in the sensitivity tests. Each file corresponds to a specific combination of model cost parameters, and the filename follows this mask: OC_Ct__DS_ST_NDU__.txt The parameters OC_cost, DS_cost, ST_cost follow the values listed in Table VI of the aforementioned paper. (caption: Energy cost parameters in sensitivity analysis). can be one of the 3 distributions used in the work (skewed-left, skewed-right or uniform). The used was 'default'. The used was 'default'. Again, the randomly-generated scenario values are located in the end of each file.
Data Types:
  • Dataset
  • Text
  • File Set
Mitogenome sequences assembled using raw data for two Malaysian Hippocampus kuda (HK1 and HK2). Genomic DNA was extracted using Qiagen Blood and Tissue Kit (Qiagen, Valencia, CA) following the manufacturer’s instructions. All libraries were prepared using BEST protocol as described in Mak et al., (2017) and were sequenced on an BGISEQ-500 platform (100PE). Raw sequence reads were assembled into individual mitogenome sequence using the MITOBIM v1.8 (reference genome assembly) pipelines. Mitogenome mapping quality was assessed using PALEOMIX and further annotated using MitoAnnotator and GB2sequin annotation web application. The mitogenome data is available in Genbank with the accession numbers MT221436 and MT221436.
Data Types:
  • Dataset
  • Text
Raw test data from SEAI funded ACCORD project. Results are from helical foil fatigue testing under radial load at ultimate limit state for ORPC's RivGen Power System. Load was applied at two locations along foil span to test turbine foil strength as well as composite clamp joint strength. The data highlights that the joint design is capable of handling the load applied where strain increase with cycles of load converged over time.
Data Types:
  • Other
  • Image
  • Dataset
  • Document
R scripts for organizing, analyzing, and visualizing data for the "Power and Accommodation" project
Data Types:
  • Software/Code
  • Tabular Data
  • Dataset
  • Document
Table 3 – Further characterisation of the digestates (determinations made by NRM lab)
Data Types:
  • Dataset
  • Document
Dataset for the WTI oil price, global WTI oil production, CISS, and the Kilian Index
Data Types:
  • Tabular Data
  • Dataset
  • Text