Filter Results
7 results
123 descrizionefd av
Data Types:
  • Tabular Data
  • Dataset
  • Document
Smoke Test on 17Jul2019 natscilivecustomer (Dataset-1) Smoke Test on 17Jul2019 natscilivecustomer (Dataset-2)
Data Types:
  • Other
  • Software/Code
  • Image
  • Video
  • Tabular Data
  • Dataset
  • Document
  • Text
  • Audio
Nanofibrillated cellulose (NFC) was prepared from TEMPO-oxidized bleached pulp by mechanical delamination. Sonication and ultracentrifugation was subsequently used in order to remove large aggregates. The measurements were performed using Bohlin CVO rheometer (Malvern Instruments Limited, UK). A cone-plate geometry (4 °/40 mm) was used with a gap width of 150 μm. The experiments were performed at 20 °C. The sample and geometry were covered with a plastic lid in order to prevent sample evaporation. In the amplitude sweep experiments the shear stress amplitude was increased from 5-40 Pa at a fixed frequency. The frequency sweep experiments, were performed at constant shear stress aplitude with the frequency sweeping from 0.1-40 Hz.
Data Types:
  • Tabular Data
  • Dataset
Oscillation
Data Types:
  • Software/Code
  • Tabular Data
  • Dataset
  • Text
The data were originally collected for the paper "Olfactory Response as a Marker for Alzheimer’s Disease: Evidence from Perception and Frontal Oscillation Coherence Deficit" in Ziaeian Hospital, Tehran, Iran. The study was conducted on mild AD and normal participants. This data includes EEG from 4 channels (Fp1-Fz-Cz-Pz) with A1 earlobe as reference. The sampling frequency is 200 Hz. It contains EEG segments during olfaction of two odors (Lemon and Rosewater). Each segment contains 1 second before and 2 seconds after the stimulus onset. Segments corresponding to Lemon odor are indicated by 0 and Rosewater segments are denoted by 1 in a vector inside the dataset. In addition, noisy epoch numbers are included in the dataset. The order of the channels in the dataset is as follows: Fp1 - Fz - Cz - Pz. The data is preprocessed and eye-blink artifact was removed using FastICA algorithm. Data on Iran-SIT score as well as participants' MMSE scores can be found in .xlsx file. If you used this data and found it helpful, please cite our paper.
Data Types:
  • Software/Code
  • Tabular Data
  • Dataset
Non-Linear Oscillations
Data Types:
  • Tabular Data
  • Dataset
Hybrid organic-inorganic perovskite (HOIP) exhibit low cost, versatility in fabrication methods and possess good application potential because of high power conversion efficiency. Methylammonium lead Iodide (MAPbI3) with quartz substrate thin film sample (glass encapsulated) was obtained from NC State University have been used to obtain millimeter wave (mmw) transient response at probe frequencies of 140 and 150 GHz from CIDO and BWO sources respectively. The HOIP film was produced at NC State University on May 02, 2017. In our time-resolved TR-mmWC apparatus, the glass-covered sample was excited by a 1KHz triggered 532 nm laser beam with a width of 0.7 ns with maximum fluence 10 microJoules per sq. cm and a spot size of 10mm. Transient datasets were recorded using a 6 GHz input bandwidth digitizer after amplifying Schottky detector registered radiofrequency (RF) signal due to differential absorption of the passing millimeter wave from source (normal to sample) at 140 and 150 GHz through sample. Signal averaging was done 4096 times and data were collected on 4 different dates spanning 2, 6, and 8 months and 1 year from date of manufacture. A general trend of increase in radiative and trap-assisted recombination lifetimes of charge carriers was noted, and a decrease in amplitudes were also noted after fitting data by double exponential. The fits are obtained by adding a second excitation to account for double peaks. Transient data attached are CSV files with column 1 being the pump-probe delay time (second), and column 2 being voltage response (V). The low noise amplifier gain of 15.527 dB must be accounted for June 28, 2017, December 18, 2017, and February 21, 2018 datasets and a gain of 15.91 dB must be accounted for the data file obtained on May 03, 2018 to yield the actual voltages. File with name “NCSU-Perovskite-CIDO-6-140GHz-3-26-RF-Average-FullLaserPower-June-28-2017” is obtained using a solid state IMPATT cavity oscillator operated at 140 GHz with 10 mW output power and after illuminating the sample with full laser power (22.14 mW). Filename: “NCSU-Perovskite-BWO-150GHz-1KHz-FullLaserPower-Dec-18-2017” is the average transient for the same sample obtained on December 18, 2017 but using an electrovacuum backward wave oscillator as probe source that is operated at 30% power level to transmit the same output power ~ 10 mW and further use of only about 0.32 mW for probing (in all cases using abeam splitter); Filename: “NCSU-Perovskite-BWO-150GHz-4096Sa-FullLaserPower-Feb-21-2018” is obtained for February 21, 2018 and filename: “NCSU-Perovskite-150GHz-BWO-1.6NDLaserPower-May-03-2018” is obtained in the same fashion as others except for the fact that the stimulating laser pulse fluence was reduced to ~ 0.3 microJoules per sq. cm.
Data Types:
  • Tabular Data
  • Dataset