Data for: Experimental Study on SRT Scrubbing Code in Water Coolant Pool

Published: 10 September 2020| Version 1 | DOI: 10.17632/5sr667754w.1
Contributor:
Kyle Becker

Description

This dataset contains all the decontamination factors found experimentally. This experiment set to validate the SRT scrubbing code, developed at Argonne National Laboratory, using a water coolant pool. To do this, the model was compared with the experimental data for a variety of cases. Additional to this, this study worked to analyze the effects of various parameters on the overall decontamination factor. These parameters included: bubble size, aerosol density, pool depth, aerosol concentration, aerosol size, and single bubble vs muli-bubble swarm scrubbing.

Files

Categories

Nuclear Energy, Fast Reactor, Nuclear Safety Analysis

Licence