Keil Project Code for STM32-Based PID Control of PEMFC Hydrogen Supply Pressure
Description
This program is developed using Keil uVision5 (v5) and integrated with host computer-based data acquisition and control command delivery, achieving reliable PID closed-loop control of hydrogen supply pressure in the Proton Exchange Membrane Fuel Cell (PEMFC) system. Furthermore, the control system performance is optimized by adopting the optimal parameter set iteratively obtained from offline Particle Swarm Optimization (PSO) algorithm, which effectively enhances the accuracy and stability of hydrogen pressure regulation.
Files
Steps to reproduce
This program runs on Keil uVision5 (v5) with STM32F103ZET6 development board. Connect ejector, drain valve, proportional valve, on/off valve, sensors via Dupont wires for external wiring, and note to connect external relays and DC-DC converters properly.
Institutions
- Qingdao University of Science and Technology