Experimental condensate mass flux values during the condensation of water vapor from humid air inside vertical channels formed by flat plates

Published: 23 December 2021| Version 4 | DOI: 10.17632/8zb3trjjgk.4
Contributors:
Primož Poredoš, Nada Petelin, Boris Vidrih, Tilen Žel, Qiuming Ma, Ruzhu Wang, Andrej Kitanovski

Description

This dataset represents experimental condensate mass flux values, obtainaned during experimental measurements of condensation of water vapor from humid air inside vertical channels formed by flat plates. Tables 1-3 show experimental condensation mass flux values, obtained at different operating conditions: temperature of humid air bulk flow, temperature difference between humid air bulk flow and main walls, and volume flow of humid air for three heights of vertical flat plates: 74 mm, 50 mm and 30 mm. Table 4 shows a dataset of 9 temperature measurements of the test section’s side wall on 16 locations with the height of vertical plates 50 mm. For more information about the experimental setup and the entire study related to condensation of water vapor from humid air inside vertical channels formed by flat plates, the readers are encouraged to check the published scientific article with the following DOI: https://doi.org/10.1016/j.isci.2021.103565.

Files

Institutions

Univerza v Ljubljani Fakulteta za strojnistvo

Categories

Condensation, Mass Transfer, Heat Exchanger, Non-Condensable Gas, Waste Heat Recovery System, Humidity, Water Vapor, Forced Convection

Licence