Data:2KW PEM Fuel Cell Residential Inverter

Published: 2 November 2022| Version 2 | DOI: 10.17632/928jmywvb7.2
Contributor:
Abhishek Bansal

Description

This dataset is in support of my research paper 'Design and Analysis of 2kW Residential PEM Fuel Cell Inverter '. Preprint : https://doi.org/10.36227/techrxiv.19762759.v1 Uploaded 56 datasets are : 1) 1_5_ffr 2) 1_5_voltage 3) 1_5_current 4) 1_5_efficiency 5) 1_5_stackconsumption 6) 1_5_fuelconsumption 7) 1_5_airconsumption 8) 1_5_utilizationpercent 9) 1_5_utilization 10) 1_5_flowrate 11) 1_5_i0 12) 1_5_tafel 13) 1_5_Vn 14) 1_5_Voc 15) 1_ffr 16) 1_voltage 17) 1_current 18) 1_efficiency 19) 1_stackconsumption 20) 1_fuelconsumption 21) 1_airconsumption 22) 1_utilizationpercent 23) 1_utilization 24) 1_flowrate 25) 1_i0 26) 1_tafel 27) 1_Vn 28) 1_Voc 29) 2_ffr 30) 2_voltage 31) 2_current 32) 2_efficiency 33) 2_stackconsumption 34) 2_fuelconsumption 35) 2_airconsumption 36) 2_utilizationpercent 37) 2_utilization 38) 2_flowrate 39) 2_i0 40) 2_tafel 41) 2_Vn 42) 2_Voc 43) 15_ffr 44) 15_voltage 45) 15_current 46) 15_efficiency 47) 15_stackconsumption 48) 15_fuelconsumption 49) 15_airconsumption 50) 15_utilizationpercent 51) 15_utilization 52) 15_flowrate 53) 15_i0 54) 15_tafel 55) 15_Vn 56) 15_Voc For other details like block/circuit diagram, set up, analysis, interpretation, parameters, mathematical formulae used to obtain these results etc. please refer "Research Paper".

Files

Steps to reproduce

******************************************************************************************** Caution Though the uploaded data is true,designed for the real practical scenarios only, technical familiarity is a must as it involves risks associated with handling chemical fires,chemical explosions, hydrogen fires, hydrogen explosions,high voltages, mains, electrical shock, fire hazard , personal injury and/or property damage etc. The author is not responsible if the algorithm is misunderstood or all this is copied without understanding or improperly implemented and mishappening due to it.The author is not responsible if the copied values cause mishappening. ******************************************************************************************** 1) 14 datasets each for 3 fuel pressures 1.5, 1 and 2. Prefix '1_5', '1' and 2' denote respectively 1.5 , 1 and 2 fuel pressure. 2) Fuel pressure of 1.5 bar is uploaded twice with 1.5 and 15_ prefix but at 15_ is at increased time range. 1_5 prefix files are at fuel pressure 1.5 bar for 1000 minutes time, that is , 16.66666666 hrs. 15 prefix files are at fuel pressure 1.5 bar for 5000 minutes time,that is, for 83.333333333 hrs. (3) ffr is the 'Fuel flow rate' in litres per minute (lpm). (4) voltage is the voltage generated by fuel cell stack. It is not boosted voltage. (5) current is the current generated by fuel cell stack. It is not boosted current. (6) efficiency is the efficiency of fuel cell stack. (7) stackconsumption is Stack consumption of Air and Fuel. (8) fuelconsumption is consumption of Fuel. (9) airconsumption is consumption of Air. (10) utilizationpercent isUtilization in percentage of Oxygen(O2) and Hydrogen(H2). (11) utilization is Utilization of Oxygen(O2) and Hydrogen(H2). (12) flowrate is the flow rate. (13) i0 is Exchange current. (14) tafel is the slope of tapel curve. (15) Vn is Nerst voltage of fuel cell stack. (16) Voc is open voltage of fuel cell stack

Categories

Fuel Cell, Proton-Exchange Membrane Fuel Cells, Nernst Equation, Hydrogen, Residential Building, Power Converter, Gas to Power, Combat Vehicle, Fuel Consumption, Helicopter, Power Conditioning, Drone (Aircraft), Inverter

Licence