Description
This dataset comprises three subsets containing experimental measurements from three accelerated stress test (AST) campaigns performed on compact fuel cell stacks (FCS; 22 cells, active area 30 cm², nominal power 200 W) at FCLAB, Belfort, France. The campaigns were carried out to evaluate the degradation of a small-scale fuel cell stack: two were conducted with the stack integrated in a compact system (Baltic LEV 200 W), and the third with the stack operated on a hydrogen test bench. In each campaign, the tested FCS was subjected to a typical square-wave AST protocol designed to accelerate catalyst layer and membrane degradation. During the uninterrupted AST, periodic polarization tests (steady-state load profile) and electrochemical impedance spectroscopy (EIS) measurements were performed to track the evolution of the FCS characteristics. In addition, sensor data, including voltage, current, anode pressure and cooling circuit temperature, were recorded continuously at 2 Hz throughout each campaign.
Files
Institutions
- Université Marie et Louis PasteurBourgogne, Besançon
Categories
Funders
- Agence Nationale de la RechercheÎle-de-France, Paris