Data for the paper Crystalline phases, relative masses and stoichiometry of mixed oxide cathodes determined by XRD and XRF measurements

Published: 26 February 2020| Version 1 | DOI: 10.17632/jnm3s3ms58.1
Contributors:
,
,
,
,

Description

X-ray diffraction and energy dispersion X-ray fluorescence data for cathode materials of Li-ion batteries. Samples named as Blend, Cath1, Cath2, Cath3.

Files

Steps to reproduce

1. X-ray diffraction data: Panalytical Model X'Pert Pro MPD diffractometer (XRD), under 40 kV and 30 mA, 15-90° 2teta range, angular step of 0.03°, 3 s counting time per point. 2. X-ray fluorescence data: dispersive energy Shimadzu spectrophotometer, model EDX-720, operating under 50 kV and 100 μA.

Institutions

Universidade Estadual de Londrina

Categories

Fluorescence Spectroscopy, Diffraction Measurement, Crystalline Material, Cathode Material, Chemical Compounds in Materials Science

Licence