CFS LIPPED CHANNEL BEAMS BUCKLING IN DISTORTIONAL MODES AT ELEVATED TEMPERATURES: BEHAVIOUR, FAILURE AND DSM DESIGN

Published: 9 August 2023| Version 6 | DOI: 10.17632/k7yj473vb4.6
Contributor:
Alexandre Landesmann

Description

Supplementary Data Supplementary data for this article, consisting of Annexes A, B and C, comprising a total of 15 tables (A1 to C2.3), can be found in the Mendeley free data repository, at 10.17632/k7yj473vb4.5, and provide (i) the beam numerical failure moments obtained in this work and (ii) the corresponding DSM-based predictions. Annex A: Data Concerning SCB Lipped Channel Beams at Room Temperature This annex includes three tables (A1 to A3), concerning SCB lipped channel beams at room temperature, and displays the whole set of numerical failure moments (i) obtained in this work (Table A1) and (ii) reported in [1, 2] (Tables A2 and A3). Each table provides, for the various lipped channel beams analysed, (i) the distortional slenderness value (λD), (ii) the ratio between the failure and yield moments (Mu/My), and (iii) the numerical-to-predicted failure moment ratios obtained with Eq. (2), namely Mu/MnD (a=0.23, b=1.55, c=1.45  proposed in [2]) and Mu/MnD.mod (a=0.25, b=1.51, c=1.52 - proposed in Section 5.1). Annex B: Data Concerning SCA Lipped Channel Beams at Room and Elevated Temperatures This annex includes two table sets (B1 and B2), concerning SCA lipped channel beams at room and elevated temperatures, and displays the whole set of numerical failure moments (i) obtained in this work (Tables B1.1-B1.3) and (ii) reported in [1] (Tables B2.1-B.2.3). Each individual table provides, for the various lipped channel beams analysed, (i) the distortional slenderness value (λD.T), (ii) the ratio between the failure and yield moments (Mu.T/My.T - Tables B1.1 and B2.1), and (iii) the numerical-to-predicted failure moment ratios obtained with Eqs. (4) and (5), namely Mu.T/MnD.T (Tables B1.2 and B2.2) and Mu.T/MnD.T* (Tables B1.3 and B2.3). Annex C: Data Concerning SCB Lipped Channel Beams at Room and Elevated Temperatures This annex includes two table sets (C1 and C2), concerning SCB lipped channel beams at room and elevated temperatures, and displays the whole set of numerical failure moments (i) obtained in this work (Tables C1.1-C1.3) and (ii) reported in [1] (Tables C2.1-C.2.3). Each individual table provides, for the various lipped channel beams analysed, (i) the distortional slenderness value (λD.T), (ii) the ratio between the failure and yield moments (Mu.T/My.T - Tables C1.1 and C2.1), and (iii) the numerical-to-predicted failure moment ratios obtained with Eqs. (4) and (5), namely Mu.T/MnD.T (Tables C1.2 and C2.2) and Mu.T/MnD.T* (Tables C1.3 and C2.3).

Files

Institutions

Universidade Federal do Rio de Janeiro Editora UFRJ

Categories

Database

Licence