Data for: Urinary peptidome analyses for diagnosis of chronic kidney disease in dogs

Published: 4 Jun 2019 | Version 1 | DOI: 10.17632/m7c43mw3f7.1

Description of this data

CE-MS analyses were performed using a Beckman Coulter Proteome Lab PA800 capillary electrophoresis system (Beckman Coulter, Fullerton, USA) on-line coupled to a micrOTOF II MS (Bruker Daltonic, Bremen, Germany). The electro-ionization sprayer (Agilent Technologies, Palo Alto, CA, USA) was grounded, and the ion spray interface potential was set to –4.5 kV. Data acquisition and MS acquisition methods were automatically controlled by the CE via contact-close-relays. Spectra were accumulated every 3 s, over a range of m/z 350 to 3000. In the next step the MosaiquesVisu software package was applied to deconvolute mass spectral ion peaks, because ionization produced ions at different charged states from the original urinary peptides. This deconvolution step groups these differently charged ions into single peptides with unique real mass. Only signals observed in a minimum of three consecutive spectra with a signal-to-noise ratio of at least 4 were considered. Signals with a calculated charge of 1+ were automatically excluded to minimize interference with matrix compounds or drugs. Capillary electrophoresis migration time and MS-detected mass were normalized by the definition of 950 clusters of peptides covering a range of 17.23 to 47.74 minutes in CE migration time and 807 to 16399 kDa in molecular mass. Samples were normalized by peptide abundance (intensity) calibration based on 141 endogenous internal urinary polypeptide standards displaying the highest frequency and stability in all analysed samples, to compensate for differences in hydration status and urine volume between dogs. Each polypeptide present in the list was defined by its normalized migration time [min], molecular mass [kDa], and signal intensity detected. Using a Microsoft Structured Query Language database, all detected polypeptides were deposited, matched, and annotated in order to allow for further comparison between groups. The criteria applied to consider a polypeptide identical was that within different samples, the mass deviation was lower than 50 ppm for masses < 4 kDa, 150 ppm for masses >6 kDa, and between 50-150 ppm for masses between 4 and 6 kDa. Acceptable migration time deviation was between 1 and 2.5 minutes.

Experiment data files

This data is associated with the following publication:

Urinary peptidome analyses for the diagnosis of chronic kidney disease in dogs

Published in: The Veterinary Journal

Latest version

  • Version 1

    2019-06-04

    Published: 2019-06-04

    DOI: 10.17632/m7c43mw3f7.1

    Cite this dataset

    Pelander, Lena; ljungvall, ingrid; Schanstra, Joost; Mullen, William; Syme, Harriet; BRUNCHAULT, Valérie; Zürbig, Petra; Haggstrom, Jens; Magalhães, Pedro; Buffin-Meyer, Bénédicte; Breuil, Benjamin; Klein, Julie; Elliott, Jonathan (2019), “Data for: Urinary peptidome analyses for diagnosis of chronic kidney disease in dogs”, Mendeley Data, v1 http://dx.doi.org/10.17632/m7c43mw3f7.1

Statistics

Views: 43
Downloads: 4

Categories

Clinical Nephrology

Licence

CC BY 4.0 Learn more

The files associated with this dataset are licensed under a Creative Commons Attribution 4.0 International licence.

What does this mean?

This dataset is licensed under a Creative Commons Attribution 4.0 International licence. What does this mean? You can share, copy and modify this dataset so long as you give appropriate credit, provide a link to the CC BY license, and indicate if changes were made, but you may not do so in a way that suggests the rights holder has endorsed you or your use of the dataset. Note that further permission may be required for any content within the dataset that is identified as belonging to a third party.

Report