Validation Data UT-SAFT Resolution
Published: 7 October 2024| Version 1 | DOI: 10.17632/w9rsywyd43.1
Contributors:
Hubert Mooshofer, , , Description
Experimental data obtained from the inspection of steel disks used to validate the UT-SAFT resolution formulas in the referencing paper 'UT-SAFT resolution'. The purpose is to show, that the indication size of small test reflectors matches well with the resolution formulas derived in this paper.
Files
Steps to reproduce
The mat-files contain the indication data in Matlab format resulting from FBH test defects which have been obtained by UT inspection of steel disks followed by 3D-SAFT. The Matlab code to evaluate the experimental data is included. The scripts measure their size in all directions in cylinder and beam coordinates. The top-level script is evalSaftVols.m. Details on the FBH test defects and inspection parameter are given in the referencing paper.
Categories
Ultrasonics, Non-Destructive Testing