Data set used in numerical modeling of condensation inside a horizontal tube
Published: 26 June 2019| Version 1 | DOI: 10.17632/y8bc7d8c2d.1
Contributor:
Hessam TaherianDescription
The Excel file contains the raw data resulted form more than 130 numerical model runs. The data covers the effect of mass flow rate, tube roughness, inlet quality, wall temperature, type of turbulence model, and the exterior heat transfer coefficient on the internal heat transfer coefficient and the exit quality of refrigerant. The refrigerant is R134a and the tube diameter is 8 mm.
Files
Steps to reproduce
Numerical model using ANSYS Fluent
Institutions
University of Alabama at Birmingham
Categories
Multiphase Flow, Thermal Condensation, Computational Heat Transfer