Data set used in numerical modeling of condensation inside a horizontal tube

Published: 26 June 2019| Version 1 | DOI: 10.17632/y8bc7d8c2d.1
Contributor:
Hessam Taherian

Description

The Excel file contains the raw data resulted form more than 130 numerical model runs. The data covers the effect of mass flow rate, tube roughness, inlet quality, wall temperature, type of turbulence model, and the exterior heat transfer coefficient on the internal heat transfer coefficient and the exit quality of refrigerant. The refrigerant is R134a and the tube diameter is 8 mm.

Files

Steps to reproduce

Numerical model using ANSYS Fluent

Institutions

University of Alabama at Birmingham

Categories

Multiphase Flow, Thermal Condensation, Computational Heat Transfer