Interactive toolkit for muti-objective optimization analysis of Mediterranean school buildings: thermal comfort, costs and embodied carbon
Description
This interactive toolkit derives from the R&D&I project “Ventilation strategies for improving comfort and health in schools in the context of nearly zero-energy consumption” (PID2020-117722RB-I00; https://institucional.us.es/prcoheves/), funded by the Spanish Ministry of Science and Innovation under the 2017–2020 State Plan for Scientific and Technical Research and Innovation – Societal Challenges. It provides open-access interactive HTML visualizations of a multi-objective optimization (MOO) analysis of existing public secondary schools in southern Spain. The analysis explores retrofit packages combining building envelope improvements, solar protection, operational parameters and ventilation strategies under future climate conditions. Optimization was performed using the NSGA-II algorithm for the 2030 climate scenario, considering 3 objectives: winter undercooling discomfort hours (UH), assessed using the adaptive comfort criteria of EN 16798-1:2019; summer overheating discomfort hours (OH), calculated using the adaptive relationship proposed by Barbadilla-Martín et al. (2017); and retrofit investment costs (€/m²). Pareto-optimal solutions were subsequently evaluated under the 2050 climate scenario to assess their robustness. Embodied global warming potential (GWP) was included as an environmental indicator, and a thermal balance index (TBI) was introduced to support balanced comparisons of winter and summer performance. Four climatic contexts are covered: Sevilla (452 heating degree days, HDD; 909 cooling degree days, CDD), Málaga (255 HDD; 791 CDD), Almería (245 HDD; 648 CDD), and Granada (1,157 HDD; 740 CDD). The toolkit includes four visualization types: *Dispersion*, *DispersionBalanced*, *Parallel*, and *TBI-Costs*. These enable users to explore trade-offs between thermal comfort, investment costs and embodied carbon; identify solutions meeting user-defined criteria; and compare retrofit options by climate, building orientation and other model parameters. The resource supports researchers, building designers, practitioners and public administrations in the preliminary assessment of climate-responsive retrofit strategies for Mediterranean schools. Rather than prescribing a single solution, it facilitates decision-making according to different priorities and constraints. Developed using Python 3.11, the visualizations are provided as HTML files for browser-based exploration. Users can zoom, pan, filter variables where available, inspect individual solutions, and export graphical or tabular data. The dataset is designed for independent access and interpretation and complements the associated research publication. Reference: E. Barbadilla-Martín, J. M. Salmerón Lissén, J. Guadix Martín, P. Aparicio-Ruiz, and L. Brotas, “Field study on adaptive thermal comfort in mixed mode office buildings in southwestern area of Spain,” *Building and Environment*, vol. 123, pp. 163–175, 2017. https://doi.org/10.1016/j.buildenv.2017.06.042.
Files
Steps to reproduce
Data generation and methodological background The interactive visualizations were generated through the following workflow: 1. Building stock characterization: A representative school building archetype was established from the statistical characterization of 872 schools in Andalusia, defining representative ranges of geometric, construction-related and operational parameters. 2. Parameterized building energy simulation: A calibrated and validated dynamic simulation model was parameterized to represent alternative building configurations and operating conditions. The workflow integrated DesignBuilder, EnergyPlus, jEPlus and Python-based processing. 3. Retrofit scenario definition and optimization: Alternative envelope improvements, solar protection measures and ventilation strategies were evaluated. Multi-objective optimization using the NSGA-II algorithm identified Pareto-optimal retrofit solutions by minimizing winter undercooling discomfort, summer overheating discomfort and investment costs under the 2030 climate scenario. 4. Post-processing and visualization: The optimized solutions were evaluated under the 2050 climate scenario. Embodied GWP was calculated as an additional environmental indicator, and the TBI was used to assess combined winter and summer thermal performance. The resulting datasets were processed into interactive HTML visualizations to facilitate exploration, comparison and filtering of retrofit alternatives. The optimization framework does not directly minimize embodied GWP. This indicator is calculated separately for the optimized solutions and should therefore be interpreted as an additional criterion for comparative assessment. Scope and interpretation The results represent optimized configurations of a parameterized school building archetype under the climatic and operational assumptions defined in the study. They should be interpreted as a decision-support resource for comparing retrofit alternatives, rather than as universally optimal solutions for every existing school building. The thermal discomfort indicators describe performance under the modelled free-running conditions, with ventilation strategies incorporated to address indoor air quality requirements. Heating and cooling energy demand, operational costs and operational carbon emissions were not calculated. Embodied GWP covers the product stage (modules A1–A3) and does not represent a complete whole-life carbon assessment. The TBI thresholds used in the analysis are comparative reference levels, not regulatory requirements.
Institutions
- Universidad de MálagaAndalusia, Málaga
- University of Naples Federico IICampania, Naples
- University College LondonEngland, London
- Universidad de SevillaAndalusia, Seville