T-0240 Pressure-Test Exclusion Distance: Numerical Reproducibility Dataset
Description
This dataset supports a computational reproducibility investigation of publicly available secondary implementations of pressure-test exclusion-distance calculations attributed to T-0240. The dataset contains nine numerical verification cases covering hydrostatic (H01–H04) and pneumatic (G01–G05) pressure-testing calculations. It includes input parameters, independently calculated results, comparisons with reported outputs, numerical residuals and graphical representations of calculation discrepancies. The investigation examines alternative hydrostatic expressions, including the treatment of fluid density, and pneumatic calculation conventions involving empirical coefficients, exponents, thermodynamic parameters, numerical precision and post-processing rules. The dataset is intended to support transparent verification, independent recalculation and further investigation of mathematical inconsistencies in publicly available engineering calculation resources. The analysis is based on secondary documentary sources. It does not establish the authoritative content of an original Lloyd's Register T-0240 document and does not provide validated exclusion distances for operational pressure testing. The dataset is associated with the research manuscript entitled "Numerical Reproducibility, Source Provenance and Implementation Ambiguities in Secondary T-0240 Pressure-Test Exclusion-Distance Calculations."
Files
Steps to reproduce
1. Obtain the dataset files containing the input parameters, reported reference outputs and independently calculated results for the nine verification cases (H01 - H04 and G01 - G05). 2. Review the documented calculation assumptions, units, empirical coefficients, exponents and numerical precision conventions associated with each case. 3. For the hydrostatic cases (H01 - H04), evaluate the alternative published expressions using identical input parameters, including the formulations with and without an explicit fluid-density divisor. 4. For the pneumatic cases (G01 - G05), evaluate the documented pneumatic expression using the stated coefficients, exponents, volume inputs and thermodynamic assumptions. Examine the influence of input precision and rounding conventions. 5. Compare independently calculated distances with the corresponding reported reference values and calculate numerical residuals. 6. Reproduce the comparison and residual plots using the numerical results contained in the dataset. 7. Examine the effects of alternative calculation conventions, including density treatment, numerical precision and applicable post-processing rules. 8. Interpret the results as a computational reproducibility assessment of secondary documentary implementations, not as validation of operational exclusion distances. The original authoritative T-0240 document was not available for authentication. Consequently, the reproduced calculations should not be interpreted as confirmation of the original methodology or as engineering guidance for field pressure-testing operations.
Institutions
- Heriot-Watt UniversityScotland, Edinburgh