Baseline-matched ATR-FTIR spectra (4000–400 cm−1) of human recombinant insulin aggregates formed with Cu2+ or Ca2+ in the presence and absence of egg-yolk phospholipid vesicles

Published: 13 October 2026| Version 1 | DOI: 10.17632/2w8hnzrd3w.1
Contributor:

Description

This dataset contains the full-range attenuated total reflection Fourier transform infrared (ATR-FTIR) spectra of dried human recombinant insulin (INS) aggregates, both as recorded and after baseline matching, together with the design table that identifies each specimen. Aggregation was induced by heating and stirring in the presence of CuCl2 or CaCl2 at 0–100 µM, with and without egg-yolk phospholipid small unilamellar vesicles (SUVs); unheated insulin dried in the same way is included as the native reference. The archive from which these spectra are taken also held bovine serum albumin and concanavalin A as secondary-structure references; those are not part of this deposit. Repeated scans of the same dried specimen were averaged, leaving 169 independent preparations (146 heated, 23 unheated), each covering 4000–400 cm−1 at a 1 cm−1 data interval (3601 points). The spectra as recorded do not share a baseline: the mean absorbance over the transparent window 1800–2250 cm−1 ranges from −0.038 to +0.485 across the set, and two preparations lie an order of magnitude away from the remaining 167. A quadratic was therefore fitted by least squares to the ranges that carry no analysed band — 1330–1475, 1710–2800, 3000–3100 and 3500–4000 cm−1, 1839 of the 3601 recorded points — and subtracted from each spectrum in full. The between-preparation standard deviation over those ranges falls from 0.0650 to 0.0048. Below 1330 cm−1 there is no anchor, so the correction there is an extrapolation and the fingerprint region should not be used quantitatively. Both the raw and the corrected spectra are provided so that any alternative correction can be applied to the same starting data. Sheets: README — what each sheet contains and the correction parameters samples — one row per preparation: column name, state (heated or unheated), metal ion, concentration, presence of SUVs corrected — wavenumber in column 1, then 169 baseline-matched spectra raw — the same 169 spectra as recorded, in the same column order These data underlie the analysis reported in the related publications listed with this dataset.

Files

Steps to reproduce

Steps to reproduce Specimen preparation. Recombinant human insulin was dissolved in 5 mM bis-Tris / 5 mM tricine–NaOH buffer (pH 7.5) and diluted to 0.25 mg/mL with CuCl2 or CaCl2 at a final concentration of 0–100 µM in a total volume of 4 mL. Membrane-containing specimens received 40 µL of an egg-yolk phospholipid SUV suspension adjusted to a phosphorus concentration of 1.38 mM; SUV-free specimens received 40 µL of 10 mM NaCl instead, so that the quantity of lipid offered to the protein is the same in every membrane-containing condition. Aggregation was induced at 338 K with stirring at 120 rpm for 24 h. Recovery and drying. Aggregates were collected by centrifugation at 15 000 rpm and 4 °C, redispersed in Milli-Q water to prevent salt crystallization, centrifuged again, and dried in a desiccator for at least seven days. Unheated (neat) insulin was dried in the same way. Acquisition. Spectra were recorded on a PerkinElmer Frontier T spectrometer with a universal ATR accessory, 400–4000 cm−1, resolution 4 cm−1, data interval 1 cm−1, 256 scans, at room temperature under a contact force of 100 N. Averaging of repeated scans. Columns whose names differ only by a trailing index were treated as repeated scans of one dried specimen when the largest absolute difference anywhere in 400–4000 cm−1 within the group was below 0.010 absorbance units; each such group was replaced by its mean. Observed within-group spread was 0.003–0.007 absorbance units against 0.037–0.064 between group means. This left the 169 preparations in the raw sheet. Baseline matching (reproduces corrected from raw). For each spectrum independently, define the anchor mask as the union of 1330–1475, 1710–2800, 3000–3100 and 3500–4000 cm−1 (1839 points). Rescale the wavenumber axis as x = (ṽ − mean(ṽ)) / (max(ṽ) − min(ṽ)) over the full recorded range. Fit a second-order polynomial in x to the anchored points by ordinary least squares, evaluate it over the whole range, and subtract it from the spectrum. Choice of order. Order 2 was chosen rather than 3: raising the order halves the residual within the fitted ranges, from 0.0275 to 0.0148, but quadruples the excursion of the fitted curve away from a straight chord inside the unfitted gaps, from 0.0018 to 0.0074. Those gaps are the amide I/II, C–H and O–H/N–H windows, so order 2 keeps the baseline from moving under the bands to be analysed. Check. After subtraction, the mean absorbance over 1800–2250 cm−1 runs from −0.044 to −0.005 (SD 0.0046, against 0.0635 before), the between-preparation standard deviation over the fitted ranges falls from 0.0650 to 0.0048, and the two extreme preparations come to −0.044 and −0.025, within the range of the rest.

Institutions

Categories

Amyloid, Absorption Spectroscopy

Licence