Volatile chemistry of the defensive secretions of millipedes common in China
Description
This data set includes GC-MS chromatograms of 6 species of millipedes, including three species of Glyphiulus sp. (namely Glyphiulus sp. 1, Glyphiulus sp. 2, and Glyphiulus paramulunensis) from the order Spirostreptida, two species from the order Spirobolida (namely Trigoniulus corallinus and Paraspirobolus lucifugus), and Nepalmatoiulus sp. representing the order Julida. The sample names correspond to declared in the captions of published Figures in a chemical ecology manuscript in the journal Pesticide Biochemistry and Physiology (DOI: 10.1016/j.pestbp.2025.106670; linked at the end). Also, some videos of their interactions with ant workers of red imported fire ants (RIFA) are included.
Files
Steps to reproduce
- All arthropods were collected and bioassayed in China. The millipede species Glyphiulus sp. 1 were collected from Yangshan County, Qingyuan City, Guangdong Province (24.468328° N, 112.6360737° E). Glyphiulus sp. 2 were collected from Hechuan District, Chongqing City (29.9746891° N, 106.272238° E). Glyphiulus paramulunensis were collected from Huanjiang County, Hechi City, Guangxi Zhuang Autonomous Region (24.828949° N, 108.254525° E). Nepalmatoiulus sp. were collected from Huangpu District, Guangzhou City, Guangdong Province (23.225205° N, 113.424745° E). Paraspirobolus lucifugus and Trigoniulus corallinus were collected from South China Agricultural University, Tianhe District, Guangzhou City, Guangdong Province (23.157731° N, 113.357815° E). - Identification of Chemical Composition of Millipede Defensive Secretions. Each millipede was frozen at -20 ℃ for 10 min, and then transferred it to a 2 mL centrifuge tube containing 0.5 mL of hexane (≥99.0% purity; Shanghai Macklin Biochemical Co. Ltd, Shanghai, China) for extraction at room temperature for 15 minutes. Subsequently, a small amount of sodium sulphate (99.0% purity; Shanghai Macklin Biochemical Co. Ltd, Shanghai, China) was added to the extract solution and stirred for 2 min to remove any remaining water. The extract solution was filtered through polytetrafluoroethylene membrane (PTFE; Dongguan Kelude Innovation Technology Co. Ltd, Dongguan, China) with a pore size of 0.45 μm and transferred into another screw-cap clean glass injection vial (Zhejiang ALWSCI Technology Co., Ltd, Zhejiang, China). Finally, the crude extract was stored in a freezer at -20 ℃ until it was used for chemical component analysis and GC-EAD analysis. - The extract solution was analyzed using a gas chromatography-mass spectrometry (GC-MS) system (Agilent 8890-5977B; Agilent Technologies, Santa Clara, CA, USA) with an HP-5 ms column (30 m × 0.32 mm × 0.25 μm), using helium as the carrier gas at the flow rate 1 mL/min (99.99% purity; Guangzhou Junduo Gas Co., Ltd, Guangzhou, China). The injection volume of the samples was 1 µL. The injection port temperature was 250°C. The ionization mode for the MS analysis was set to electron ionization at 70 eV. The column interface temperature held at 280 °C the scan range was set to 50–550 m/z. The column temperature program was initiated at 50°C for 3 min, then increased at a rate of 15°C/min up to 280°C, and a final hold for 6 min. Arthropods were bioassayed inside Petri dishes, by observing direct confrontation and registering the perished bugs soon after. Please, refer to the main manuscript below for any specific details.
Institutions
- South China Agricultural UniversityGuangdong, Guangzhou
- Guangdong Academy of ForestryGuangdong, Guangzhou
- Universidade Estadual de GoiasGO, Anapolis