Impact of microstructural stability on the creep behavior of cast Al-Cu alloys

Published: 3 September 2019| Version 2 | DOI: 10.17632/47bvprbmsc.2
Contributor:
Brian Milligan

Description

Creep data used in the Materials Science and Engineering: A publication of the same name.

Files

Steps to reproduce

Second column is timestamp in hours, fourth and fifth columns are raw extensometer readings. Extensometer readings must be multiplied by 0.005 for all tests except Al-7Cu large grain to provide values in inches. The Al-7Cu large grain extensometer readings should be multiplied by 0.02 instead. This difference is due to performing the Al-7Cu large grain test on a different creep frame. Gage length is 1.25 inches.

Institutions

Oak Ridge National Laboratory

Categories

Metallurgy

Licence