data for: Perfluorinated Colloidal Flame-Retardant Electrolytes with High Lithium-Ion Transference Numbers for Stable 5 V-Class Lithium Metal Batteries
Description
Battery cycling and electrochemical data,including long cycle data LNMO 3.024mg cm2,Long-cycle data of lithium symmetric batteries,CV and EIS
Files
Steps to reproduce
All galvanostatic charge/discharge tests were performed using a Neware battery testing system (Neware, China). Cyclic voltammetry (CV)and electrochemical impedance spectroscopy (EIS) measurements were conducted using a BioLogic electrochemical workstation (EC-Lab). Multi-cycle CV tests for Li|LNMO batteries were carried out at a scan rate of 1 mV s-1within a potential window of 3.0-4.95 V. EIS measurements of Li|LNMO cells were recorded over a frequency range of 1 MHz to 0.1 Hz. Long-term cycling stability was evaluated via galvanostatic charge/discharge methods, with current densities and voltage ranges specified in the respective figure captions.
Institutions
- Hefei University of TechnologyAnhui, Hefei