MCP-iBAT: field measurements on twin full-scale test cells with a PCM coating in Reunion Island (2020–2026)

Published: 9 November 2026| Version 1 | DOI: 10.17632/7gv2ynbhjh.1
Contributors:
,
,
,
,
,

Description

This dataset contains almost six years (June 2020 – March 2026) of 10-min field measurements on two identical full-scale test benches located in two contrasting tropical climates of Reunion Island (France): Saint-Pierre (coastal lowlands, 60 m a.s.l., 21.3408° S, 55.4911° E) and Le Tampon (mid-altitude, 670 m a.s.l., 21.27° S, 55.50° E). Each bench (5.86 × 2.88 × 2.57 m) is made of lightweight steel–polyurethane sandwich panels and divided into two twin, unoccupied and closed cells. In cell B, the inner surface of the sun-exposed north wall (6.86 m²) is coated with a commercial plaster containing a microencapsulated paraffin phase change material (PCM, Enerciel®, 3–5 mm). Cell A, without PCM, is the reference. Short periods recorded before the coating was applied (June 2020 at Saint-Pierre, July–August 2020 at Le Tampon) are included. Measured variables: - inner surface temperatures of all walls, ceiling and floor, and inner and outer surface temperatures of the north walls (type T thermocouples); - indoor air temperature at two heights (thermocouples) and, at Saint-Pierre until September 2023, indoor air temperature and relative humidity (Testo 175 H1); - at Saint-Pierre from July 2021, outer surface temperatures of the other walls, floor and roof, and air temperature in the ceiling void; - conductive heat flux density at the inner surface of the walls and ceiling (Hukseflux HFP01SC heat flux plates); - on-site weather: air temperature and relative humidity, global and diffuse horizontal irradiance, long-wave irradiance, wind speed and direction, rainfall, atmospheric pressure. Files: - MCPiBAT_SaintPierre_20200612-20260308.csv and MCPiBAT_LeTampon_20200724-20260307.csv: one file per site, one row every 10 min (UTC time stamps), with a Configuration column (NoPCM / PCM), an AirConditioning flag (short air-conditioning test at Saint-Pierre, 26–29 July 2021) and harmonised, self-explanatory column names (e.g. q_B_NorthWall_in_FLUX6096); - MCPiBAT_variable_dictionary.csv: unit, description, sensor, original identifier, period of availability and statistics of each variable; - README.txt: description of the files and of the column naming. The data are 10-min averages of 1-min records; invalid channels and values were removed and no gap-filling was applied. The dataset can be used to study the in-situ behaviour and ageing of a PCM-enhanced envelope under tropical conditions, to identify phase-change parameters from field measurements, and to calibrate and validate building energy simulation models. The data were collected within the MCP-iBAT project (PIMENT laboratory, University of Reunion Island) and are described in detail in a Data in Brief article.

Files

Steps to reproduce

1. Experimental setup: two identical prefabricated test benches (Saint-Pierre and Le Tampon, Reunion Island), each divided into two twin cells (A: reference; B: microencapsulated PCM coating on the inner face of the north wall). The cells are unoccupied, closed and free-running (no internal gains; no heating or cooling, except an air-conditioning test at Saint-Pierre on 26–29 July 2021, flagged in the AirConditioning column). 2. Sensors: type T thermocouples made and calibrated in the laboratory (±0.1 °C) on the walls, ceiling, floor, roof and on a vertical measurement line at the centre of each cell (about 0.80 m and 1.60 m above the floor); Hukseflux HFP01SC-05 heat flux plates fixed on the inner surfaces with aluminium tape and a thin layer of thermal paste; Testo 175 H1 temperature/humidity loggers; on-site weather stations of the PIMENT laboratory. 3. Acquisition: Campbell Scientific CR3000 data loggers, scan rate 0.1 Hz, 1-min averages, stored in the database of the PIMENT laboratory. 4. Processing: records extracted from the database, averaged over 10 min (mean of the ten 1-min records), merged with the weather data on a common UTC time base and gathered into one file per site with a continuous 10-min time base. Column names were harmonised (<Q>_<Cell>_<Element>_<Position>_<Sensor>; weather: Met_<Quantity>). 5. Filtering (Python, pandas): removal of invalid or undocumented channels (sensors with constant values, data-logger and weather-station housekeeping channels, faulty weather channels); removal of error codes (−100), values outside physical bounds, isolated spikes (deviation from the 1-h moving median) and flat lines (identical values for ≥ 24 h, or ≥ 6 h for outdoor air temperature and humidity). About 15,300 values (0.05 %) were removed. No gap-filling or other correction. 6. Use: read the CSV files with any tool (comma separator, decimal point, empty field = missing value). Convert Time_UTC to local time with UTC+4. Use MCPiBAT_variable_dictionary.csv to find units and the period of availability of each variable. The raw export and the processing script are available from the authors on request.

Institutions

Categories

Energy Efficiency, Heat Transfer, Building Physics, Thermal Energy Storage, Phase Change Material, Tropical Habitat, Building Engineering

Funders

Licence