LATERAL-TORSIONAL FAILURE AND DSM DESIGN OF CFS LIPPED CHANNEL BEAMS AT ROOM AND ELEVATED TEMPERATURES

Published: 5 April 2024| Version 1 | DOI: 10.17632/7mbrnyzvkz.1
Contributor:
Alexandre Landesmann

Description

It consists of three Annexes (A, B and C), comprising a total of 15 tables (A1 to C4) – each table provides, for the various lipped channel beams considered, (i) the global slenderness value (λG), (ii) the ratio between the failure and yield moments (Mu/My), and (iii) the numerical-to-predicted failure moment ratios obtained. Annex A concerns all beams at room temperature analysed in this work and in [1]. Annex B concerns all beams at elevated temperatures analysed in this work. Annex C concerns SCA beams at elevated temperatures analysed in [2].

Files

Institutions

Universidade Federal do Rio de Janeiro Editora UFRJ

Categories

Database

Licence