Design files and specifications for an MRI-compatible electrode implantation system supporting behavioral neurophysiology and EM-fMRI in macaques

Published: 25 October 2026| Version 1 | DOI: 10.17632/b4mnd7mbjf.1
Contributors:
,
,

Description

This dataset provides design files and technical specifications for an MRI-compatible electrode implantation system developed for behavioral neurophysiology and electrical microstimulation-evoked functional MRI (EM-fMRI) in macaques. The dataset is organized into three folders: (1) Ceramic guide tubes, containing dimensional and manufacturing specifications for custom zirconia and alumina tubes; (2) Chamber and grid, containing seven manufacturer-provided engineering drawings in PDF format and a component index; and (3) Electrode holder, containing an author-designed STL model and fabrication information. These materials are provided to facilitate the understanding and reproduction of the implantation system. Detailed descriptions of the implantation procedures and experimental validation are provided in the associated research article.

Files

Institutions

Categories

Neuroscience, Methodology

Funders

Licence