Three-Storey Shear-Type Frame Ambient Vibration Measurements [Steel]
Description
Acceleration data files from ambient vibration measurements from a three-storey shear-type Frame. Three different measurement conditions: (1) Linear Data from Model in Sound Condition (Two sets of 42 records each). (2) Non-linear record from model suffering simulated structural damage (Single acquisition). (3) Linear Data from Model in Damaged condition (Two sets of 42 records each). All the datasets belongs to the research project: "TIME-DEPENDENT DYNAMIC IDENTIFICATION: A NEW APPROACH FOR STRUCTURAL HEALTH MONITORING THROUGH AMBIENT VIBRATION MEASUREMENTS", developed under supervision of the Institute for Sustainability and Innovation in Structural Engineering (ISISE), with funding from the Chilean National Agency for Research and Development (ANID), under reference ANID BECAS/DOCTORADO EXTRANJERO 72204431. All laboratory test were conducted in the facilities of the LEST laboratory from the Civil Engineering Department of University of Minho, Guimarães, Portugal.
Files
Steps to reproduce
The measured specimen consists of a three-storey shear-type frame, featuring a total height of 900 mm and an inter-storey height of 300 mm. Floors consist of 400 mm × 200 mm × 10 mm steel plates, each supported by four columns of 40 mm width and 3 mm thickness. Two additional 50 mm long steel plates, welded at the edges of the floor plates, allow connection with the columns. Each column is maintained into place by two bolts at the top and two bolts at the bottom, spaced 20 mm between them and located at a distance of 10 mm under/over the floor plates. All the columns and floor plates are made of the same type of steel and no characterisation of the material properties was conducted. Two sets of linear data measurements were carried out to acquire the structural response in different stiffness configurations, corresponding to an initial sound condition and a subsequent damage condition of the frame, where damage was induced through the removal of two bolts located just below the second storey of the shear model. Additionally, a single 20 minute non-linear data acquisition was conducted capturing the simulated structural damage being induced. The experimental setup for dynamic testing, consists of three mono-axial piezoelectric accelerometers deployed at the top of the column level to measure movements in the plane direction. Each set of linear data measurements consists of 42 records performed during daytime and 42 records performed during nighttime, in order to acquire signals with different signal-to-noise ratios. Each acquisition featured ten minutes duration and 52 kHz sampling rate, corresponding to the maximum sampling rate of the data acquisition system. Based on a preliminary identification of the modes of interest, signals were later decimated up to 100 Hz, resulting into three-channel records with 60.000 data points per channel.
Institutions
- Universidade do Minho Escola de EngenhariaGuimaraes
Categories
Funders
- Agencia Nacional de Investigación y DesarrolloSantiago Metropolitan, ChileGrant ID: ANID BECAS/DOCTORADO EXTRANJERO 72204431