Direct CO₂-to-CO Conversion from Monoethanolamine: Effects of Flue Gas, Heat-Stable Salts, and Cetyltrimethylammonium Bromide

Published: 12 October 2026| Version 1 | DOI: 10.17632/gh6z2zbkm2.1
Contributors:
,
,
,
,
,

Description

These are the Supplementray Data for the submission of the manuscript with the titele above and the abstract: Direct electrolysis of amine-captured CO₂ could bypass energy-intensive solvent regeneration, but previous studies have predominantly relied on small laboratory cells and specialized catalyst architectures under simplified conditions. Here, CO₂-loaded monoethanolamine (MEA) was electrolyzed in a comparatively large 25 cm² liquid-fed flow cell using commercially available Ag foam and IrO₂/Ta₂O₅-coated titanium electrodes. To the best of our knowledge, this work represents the first systematic investigation of representative heat-stable salt effects during captured-CO₂ electrolysis at this scale. The technically relevant platform was used to investigate the effects of cetyltrimethylammonium bromide (CTAB), O₂-containing simulated flue gas, and selected heat-stable salt anions in application-relevant 30 wt% MEA. Addition of 0.3 mM CTAB increased the Faradaic efficiency for CO (FECO) from approximately 2% to 17%, whereas 2 M KCl provided no improvement. Cyclic voltammetry, electrochemical impedance spectroscopy, and potential-dependent gas chromatography indicate that quaternary ammonium species modify the Ag/electrolyte interface and preferentially suppress hydrogen evolution. O₂-containing simulated flue gas substantially decreased FECO through reduced CO₂ availability, competing oxygen reduction, and associated interfacial changes. All investigated heat-stable salt anions decreased CO selectivity. Sulfate exerted a comparatively moderate effect, whereas acetate altered the CTAB-containing interfacial response in a strongly potential-dependent manner. Nitrate showed evidence of a competing cathodic Faradaic pathway, with approximately 10% of the transferred charge remaining unassigned. Complementary variation of MEA concentration and flow rate of catholyte yielded a maximum FECO of 26% in 1 M MEA. These findings reveal gas composition and solvent impurities as critical limitations and establish design requirements for scalable, robust, and impurity-tolerant capture-conversion systems.

Files

Steps to reproduce

Chemicals and materials Monoethanolamine (≥99.5%), cetyltrimethylammonium bromide (≥99%), anhydrous sodium sulfate (≥99%), sodium acetate (≥98.5%), sodium nitrate (≥99%), and potassium hydroxide (≥85%) were purchased from Carl Roth GmbH + Co. KG and used without further purification. Aqueous solutions were prepared using deionized water. All gases, synthetic gas mixtures, and calibration gases were supplied by Air Products GmbH. For cyclic voltammetry and electrochemical impedance spectroscopy, silver sheets (0.1 mm thickness; Carl Roth GmbH + Co. KG) were cut into 4 mm × 70 mm strips. Glassy carbon electrodes (10 mm × 70 mm × 3 mm; IKA-Werke GmbH & Co. KG) and a RE-1B Ag/AgCl reference electrode (in 3 M NaCl; C3 Prozess- und Analysentechnik GmbH) were also used. For flow-electrolysis experiments, silver foam (geometric area: 25 cm2) supplied by Alantum Europe GmbH was used as the cathode, while an IrO₂/Ta₂O₅-coated titanium mesh (geometric area: 25 cm2) supplied by Shanxi Jiayuan Technology Co., Ltd. served as the anode. The electrode compartments were separated by a Fumasep FKB-PK-130 cation-exchange membrane supplied by Fumatech BWT GmbH. CO₂-absorption protocol All electrochemical experiments were conducted using fully CO₂-loaded 30 wt% aqueous MEA solutions prepared under controlled conditions. A 100 mL aliquot of MEA solution, with or without defined concentrations of CTAB, was placed in a fritted gas-washing column maintained at 5 °C and initially purged with N₂. The electrolyte was subsequently loaded at a constant total gas flow rate of 35 mL/min using either high-purity CO₂ (99.999 vol%) or a synthetic flue-gas mixture containing 15 vol% CO₂ and 10 vol% O₂ in N₂. The gas flow was controlled using a Bronkhorst F-201CM mass flow controller. Complete loading was defined by stable CO₂ breakthrough, indicated by identical inlet and outlet CO₂ concentrations, and was independently confirmed by gravimetric mass uptake. Flow electrolysis Impurity screening was performed in a zero-gap flow cell equipped with 5×5 cm titanium pin-type flow fields, a silver-foam cathode, an IrO₂/Ta₂O₅-coated titanium-mesh anode, and a cation-exchange membrane. Both electrodes had a geometric area of 25 cm². The anolyte consisted of 40 mL of 1 M KOH, while the catholyte comprised 40 mL of fully CO₂-saturated 30 wt% aqueous MEA containing 0.3 mM CTAB and defined concentrations of heat-stable salts as synthetic impurities. The additives were introduced after completion of CO₂ absorption and immediately before electrolysis. Both electrolytes were recirculated at 18 mL min−1 using Verder V-MD10 pumps. After N₂ purging, electrolysis was conducted galvanostatically (300 mA, geometric current density: 12 mA cm−2) at room temperature. Cathodic gas volume was quantified by water displacement using a custom-built eudiometer.

Categories

Chemistry, Electroanalytical Chemistry

Licence