FBG accelerometer characterization: swept-sine, discrete-frequency and unexcited records

Published: 25 October 2026| Version 1 | DOI: 10.17632/gxpywjg5hs.1
Contributors:
Kaio Fábio,
,
,
,
,

Description

This dataset contains the optical interrogation records of a push-pull double-hexagon fiber Bragg grating (FBG) accelerometer under controlled shaker excitation, together with the simultaneous records of a co-mounted calibrated reference accelerometer. It allows the sensitivity, frequency response, linearity, resonance and noise floor of the transducer to be derived from raw wavelength data. Instrumentation. The device under test carries two FBGs, one on each of two hexagonal stages mounted on opposite faces of a common inertial mass, so that the gratings deform in opposition. Excitation came from a TIRA TV 51110 electrodynamic shaker driven by a Tektronix AFG3021C generator. A LUNA OS7230 FBG accelerometer (calibrated at 94.380287 pm/g, operating range 5 to 1000 Hz, resonance above 1300 Hz) was mounted on the same armature face and read through a separate channel. All channels were acquired by a LUNA Hyperion si255 interrogator at 5 kHz with 2 pm resolution. Contents. 148 recordings in three groups. Three unexcited records (ground_1 to ground_3), 20 minutes each with the shaker off, for the noise floor. One swept sine (sweep_40_2500_500mV), a 120 s linear sweep from 40 to 2500 Hz at a 500 mV drive, for the resonance and the flat-band edge. And 144 discrete-frequency records (sin_frequency_drive_repetition) of 30 s each, at 40, 100, 200, 400, 600, 900 and 1200 Hz with three repetitions per point. The drives are 125 mV, 250 mV, 500 mV, 1 V, 2 V and 3 V, with 5 V and 7 V added at 400, 600 and 900 Hz. The drive is set in volts because the shaker output does not map linearly onto acceleration, which is why the reference is recorded alongside every acquisition. Format. Tab-separated text exported by the interrogator, with a 65-line header, a comma as decimal separator and wavelengths in nanometres. Three peak columns matter: CH3 Peak 1 and CH1 Peak 5 are the two prototype gratings, CH5 Peak 1 is the reference. The accelerometer signal is the difference between the two prototype columns, which cancels the common-mode thermal term. Acceleration in g follows from the reference column divided by 94.380287 pm/g. File names end with the acquisition timestamp, YYYYMMDDHHMMSS. Validity of the reference channel. The reference accelerometer has a declared operating range of 5 to 1000 Hz and a resonance specified only as a lower bound of 1300 Hz, so its own magnification departs from unity beyond roughly 390 Hz. Absolute sensitivity should therefore be derived from the 54 records at 40, 100 and 200 Hz, where the reference is unambiguously inside its linear range. The 90 records at 400 Hz and above are included as raw data and remain useful where the reference is not needed as an absolute scale, such as relative frequency-response work, repeatability analysis or comparison against a wider-band reference.

Files

Institutions

Categories

Fiber Bragg Grating, Optical Sensor, Mechanical Vibration

Licence