A unified framework for thermoelectric cooling optimization across thermal boundary conditions

Published: 16 October 2026| Version 3 | DOI: 10.17632/hvtdy6v4mg.3
Contributor:
Haiyang Li

Description

Supporting data and original code for “A unified framework for thermoelectric cooling optimization across thermal boundary conditions”. Download ECM data and code.zip (7.12 MB) for numerical data and verification/reproduction code. Download ECM COMSOL models.zip (529.34 MB) for the 44 original solved models. Extract both archives into the same folder to retain Models/, Data/ and Code/ paths. Version 3 adds the complete analytical scenario grid for SI Figure S11 and Table S11: 57 declared scenarios, 56 attained optima, one infeasible state and all 67 maximizing states, including ties. It includes the 61 retained straight-leg source records, a data dictionary, verification records, portable read-only verification and plotting code, and PDF/SVG figure masters. Four zero-drive COP cutoff diagnostics are retained as provenance but excluded from the finite peak-COP grid because their low-current limits are unbounded. The earlier 22-case benchmark, 45,761 response samples across 28 allowed intervals, all 44 matched-current FEM outputs, refinement and branch records, sensitivity data, original solver code and model archive are preserved. This extension adds no FEM or experimental validation. Data, documentation and author-owned model configurations use CC BY 4.0. Original code uses MIT. COMSOL and external dependencies are excluded. Readme.md, dictionaries, figure/source maps and checksum manifests document contents, units, provenance and scope.

Files

Steps to reproduce

Extract ECM data and code.zip. Run python -B Verify.py from its root to check core hashes, model/result provenance, case matching and retained numerical records. Add --analytical with NumPy and SciPy to recompute the 45,761 benchmark responses, saved sensitivity data and S30 averages. For the complete Figure S11/Table S11 extension, run python -B "Code/Extended scenario grid/Verify S11.py" with NumPy and SciPy. It recomputes all 57 scenarios, checks all 67 maximizers, compares stationary/boundary candidates and tests the excluded low-current COP diagnostics without modifying data or launching COMSOL. Run python -B "Code/Extended scenario grid/Plot S11.py" with matplotlib to reproduce the four panels in Reproduced figures/Fig.S11 beside the extracted package. Approved vector masters are in Figures/SI/Fig.S11/. To check native model bytes, extract ECM COMSOL models.zip into the same root and run python -B Verify.py --models; combine --analytical --models for both checks. Default core checks do not verify actual model bytes. Reusing MPH models or FEM Java sources requires COMSOL Multiphysics 6.3 and the licensed interfaces described in SI Section S7.1. Configure local paths as described in Readme.md.

Institutions

Categories

Thermoelectric Refrigeration

Licence