Validity of smartphone step counts application : validity, error and reliability
Description
We hypothesised that smartphone step-counting accuracy in adults depends on carrying position and walking conditions, with the pelvic/pocket area best and arm worst. Aims: asses criterion validity measurement error and reliability against validated references, and test the effect of placement. Structured extraction from 60 published validation studies (2010-2026; 2543 participants; 76 applications). six databases were searched from 1 january to 1 july 2026 (PROSPERO CRD420251183478). Two reviewers independetly screened and extracted, per result (on smartphone-application-placement-test condition combination): reference device, walking speed, setting and reported metrics (correlation, ICC, MAPE, bias, limits of agreement). Quality was rated with COSMIN Risk of Bias. Result were rated Sufficient, Insufficient or Indeterminate against pre-defined thresholds (r > 0.70 without significant difference; MAPE < 10% or bias < 5% with LoA Within +/- 20%; ICC > 0.70). Certainty was graded with COSMIN-modified GRADE. Only Adequate or Very studies were synthetised (31 validity, 46 error, 11 reliability). Pelvic placement was most consistent (Sufficient: 80/134 error, 12/17 reliability, but only 21/95 validity results). Pocket carriage showed acceptable error and reliality but weak validity (4/86). Hand and arm performed worst. Accuracy was poor at slow speed (27/34 error results insufficient) and in real life (22/33), but good at moderate/fast speeds. Correlations up to 0.99 often coexisted with significant systematic differences. Certainty was low for validity and very low for error and reliability. Rows are results not participants (supplementary table S3 cosmins results) : counts show conditions meeting thresholds, not proportions of people. Results are not fully independent (several apps read the same operating-system step count) and references differ (direct counts are exact; pedometers and accelerometers carry error). error metrics were too heterogeneous to ppol, so synthesis is descriptive. The data support trend monitoring with the phone at the waist, not replacing research-grade accelerometers for individual measurement, and should not be generalised to clinical populations (44/60 studies enrolled healthy adults only). The placement ranking is a trend, not a firm hierarchy.
Files
Steps to reproduce
Design and protocol. Systematic review following PRISMA 2020 and PRISMA-COSMIN for Outcome Measurement Instruments 2024. The protocol was registered on PROSPERO (CRD420251183478) before data extraction. Six databases (CINAHL, Embase, PubMed, Scopus, SPORTDiscus, Web of Science Core Collection) were searched by two researchers for publications in French, English or German from 1 January 2007 to 1 July 2026. Strategies followed the PIRD framework (Population, Index test, Reference test, Domain of interest) and combined three concepts: device (smartphone, mobile phone, iOS/Android, named applications), outcome (step count, gait, walking, physical activity) and measurement property (validity, accuracy, reliability). Boolean operators, controlled vocabulary (MeSH, Emtree) and free text were adapted to each platform. Records were imported into Covidence for deduplication and screening. Two reviewers independently screened titles/abstracts, then full texts; disagreements were resolved by discussion or a third reviewer. Eligibility: ambulatory adults (≥ 18 years), smartphone step counting, a validated reference (research-grade accelerometer, instrumented walkway, certified inertial unit, or direct counting), and agreement metrics. 4,097 records led to 60 included studies. Two reviewers independently used a standardised form, piloted on the first three studies: population, smartphone model, application, placement, reference device, walking task (speed, distance, environment) (Data are in Supplementary Table S1). Then statistical methods and reported values (correlation, ICC, bias, MAPE, limits of agreement) (Data are in Supplementary Table S3). Study quality was assessed independently by two reviewers in Covidence with the COSMIN Risk of Bias checklist (worst score counts). Each result (smartphone–application–placement–test condition) was rated Sufficient, Insufficient or Indeterminate against pre-defined thresholds (r ≥ 0.70 with no significant difference; MAPE ≤ 10% or bias ≤ 5% with LoA within ±20%; ICC ≥ 0.70), based on COSMIN and INTERLIVE recommendations. Only Adequate or Very good studies were synthesised (Supplementary Tables S2–S3). Results were grouped by placement and speed (slow < 0.8, moderate 0.8–1.8, fast > 1.8 m/s; other; real life). Certainty was graded with the COSMIN-modified GRADE approach.
Institutions
- Université de LimogesNew Aquitaine, Limoges