Radial Dose Profile of a Y-90 Sphere
Published: 3 October 2018| Version 3 | DOI: 10.17632/kmczwffk4s.3
Contributor:
Hugo Pérez-GarcíaDescription
This file contains the raw data of a radial dose profile of a sphere of Y-90 designed by Therasphere, obtained by Monte Carlo simulation with the code PENELOPE (2011). From this file, you can build a 3D kernel of any voxel size according to the methodology described in the article (actually in publication process): Methodology to perform and Yttrium-90 radioembolization dosimetry using a radiotherapy treatment planning system (TPS) Perez-Garcia H, Castro J, Molina MY, Ruiz S, Maldonado A, Fuertes S, Vera U, Cano R, Fernández A, Sánchez J, González JF
Files
Steps to reproduce
It is a .dat file, encode in ANSI. The comments start the line with #. Units and magnitudes are described in the file itself
Institutions
Hospital Universitario Quironsalud Madrid
Categories
Medical Physics, Dosimetry, Monte Carlo Method, Treatment Planning, Yttrium