Tellurium absorption atlas
Published: 15 February 2022| Version 1 | DOI: 10.17632/kmkbwtjhd3.1
Contributor:
Amanda RossDescription
Fourier transform absorption spectrum of 130Te2, recorded at about 625 °C. Data columns are vacuum wavenumber, transmittance and absorbance.
Files
Steps to reproduce
Spectra were recorded in a Fourier transform spectrometer, using a halogen white light souce and a 10-cm quartz cell containing a small sample of 130Te. It is hoped that these data provide a convenient secondary spectral calibration standard for Doppler-limited applications in the blue/violet spectrum, as an alternative to the widely-used printed atlas by P. Luc and J. Cariou, 'Atlas du spectre d'absorption de la molécule de tellure', CNRS, Laboratoire Aimé Cotton (1980)
Institutions
Universite Claude Bernard Lyon 1
Categories
Atlas, Molecular Spectrum