Neutron induced single event effects in optocouplers

Published: 29 October 2026| Version 1 | DOI: 10.17632/kw8r2c8w5y.1
Contributor:
Yongfang Lai

Description

This dataset contains the experimental data from broad-spectrum neutron irradiation tests on optocouplers (model JC3H7-C) conducted at the Atmospheric Neutron Irradiation Spectrometer (ANIS) facility of the China Spallation Neutron Source (CSNS). The data support the study "Neutron induced single event effects in optocouplers" and include: (1) raw transient voltage pulse waveforms recorded by a high-speed waveform acquisition system under both LED off-state and on-state bias conditions; (2) SET cross-section values and SET occurrence rates as functions of collector-emitter bias voltage; (3) differential cross-section energy spectra correlated with neutron time-of-flight (TOF) data; and (4) pulse waveform characteristics including amplitude, width, and rise time distributions. Data processing was performed using custom MATLAB scripts, including event detection, cross-section calculation with combined standard uncertainty estimation, Weibull distribution fitting, and energy-dependent differential spectrum construction. This dataset is provided to support result verification, method reproducibility, and further radiation reliability assessments of optocouplers in neutron environments.

Files

Categories

Radiation Damage, Neutron Irradiation

Licence