Neutron induced single event effects in optocouplers
Description
This dataset contains the experimental data from broad-spectrum neutron irradiation tests on optocouplers (model JC3H7-C) conducted at the Atmospheric Neutron Irradiation Spectrometer (ANIS) facility of the China Spallation Neutron Source (CSNS). The data support the study "Neutron induced single event effects in optocouplers" and include: (1) raw transient voltage pulse waveforms recorded by a high-speed waveform acquisition system under both LED off-state and on-state bias conditions; (2) SET cross-section values and SET occurrence rates as functions of collector-emitter bias voltage; (3) differential cross-section energy spectra correlated with neutron time-of-flight (TOF) data; and (4) pulse waveform characteristics including amplitude, width, and rise time distributions. Data processing was performed using custom MATLAB scripts, including event detection, cross-section calculation with combined standard uncertainty estimation, Weibull distribution fitting, and energy-dependent differential spectrum construction. This dataset is provided to support result verification, method reproducibility, and further radiation reliability assessments of optocouplers in neutron environments.