Aggregate Reliability Results for Zero-Shot CLIP under Controlled Geometric Perturbations
Description
This dataset accompanies the research manuscript entitled "A Backbone-Dependent Calibration Reversal in Zero-Shot CLIP under Controlled Geometric Perturbations." It provides aggregate experimental results from a systematic evaluation of zero-shot CLIP reliability under controlled geometric transformations. The study evaluates two pretrained CLIP backbones, ViT-B/32 and ViT-L/14, on Oxford-IIIT Pet and CIFAR-10 using a fixed 19-condition evaluation bank comprising one clean condition, four rotation conditions, eight translation conditions, four scaling conditions, and two cropping conditions. The dataset contains five files: 1. stage31_condition_results_corrected.csv — Condition-level evaluation summaries covering the dataset, backbone, probability state, geometric condition, sample counts, and evaluation metrics. 2. stage30_four_group_metrics.csv — Aggregate reliability metrics for the four model–dataset configurations, including comparisons between raw and temperature-calibrated probabilities. 3. stage30_selective_risk.csv — Aggregate selective-prediction results evaluated using thresholds selected on development data and applied to held-out test data. 4. ivc_oxford_calibration_interaction_posthoc.json— Post-hoc cross-backbone calibration interaction estimates and uncertainty intervals for Oxford-IIIT Pet. 5. ivc_source_transition_posthoc.csv — Descriptive source-paired correctness-transition summaries across geometric transformation families. These data support the manuscript's analysis of calibration, geometric sensitivity, and confidence-based selective prediction. The reported calibration contrasts concern the fixed 19-condition evaluation distribution. The files contain aggregate research results rather than original dataset images, per-image predictions, model logits, or private source-level arrays. They do not independently provide a complete reproduction of model inference or source-clustered bootstrap calculations. The aggregate data are released under the Creative Commons Attribution 4.0 International (CC BY 4.0) license. The original Oxford-IIIT Pet and CIFAR-10 datasets remain subject to their respective source attribution and rights conditions.
Files
Steps to reproduce
The deposited files provide aggregate evaluation results and support result-level inspection and comparison. They do not contain the individual image predictions, logits, or complete source-level bootstrap inputs required to reproduce the full investigation from scratch. To inspect the deposited results: 1. Download all five CSV/JSON files from this dataset. 2. Load the CSV files with a standard data analysis tool such as Python pandas, and load the JSON file with a compatible JSON parser. 3. Inspect stage31_condition_results_corrected.csv to examine the reported condition-level results across the fixed 19-condition geometric evaluation bank. 4. Inspect stage30_four_group_metrics.csv to compare reliability metrics between raw and temperature-calibrated predictions for the four combinations of dataset and CLIP backbone. 5. Inspect stage30_selective_risk.csv to examine selective-prediction operating points evaluated using development-selected thresholds. 6. Inspect ivc_oxford_calibration_interaction_posthoc.json for the reported post-hoc Oxford-IIIT Pet calibration interaction estimates and uncertainty intervals. 7. Inspect ivc_source_transition_posthoc.csv for source-averaged correctness-transition summaries across rotation, translation, scaling, and cropping families. The underlying study uses pretrained zero-shot CLIP ViT-B/32 and ViT-L/14 with the Oxford-IIIT Pet and CIFAR-10 datasets. Each geometric condition is evaluated independently before CLIP preprocessing, and calibration is assessed on the specified evaluation distribution. The aggregate files are intended to support verification of reported numerical results and exploratory comparisons. Reproducing the original model inference, fitted temperatures, and source-clustered bootstrap calculations requires additional experimental artifacts that are not included in this dataset.