Vacuum Integrity and Leak Localization in Polymer Composite Manufacturing

Published: 13 October 2026| Version 1 | DOI: 10.17632/r6d87xvsyp.1
Contributors:
, Francois Robitaille

Description

Vacuum infusion is widely used for manufacturing small to large polymer composite (PMC) parts. Initial evacuation, infusion and consolidation phases where liquid resin flows into a fabric reinforcement stack under negative gauge pressure, saturates the stack and cures into a laminate are well understood. However, the critical phase of the process taking place between evacuation and infusion is not well documented. The detection and localization of air ingress leaks remain poorly understood and controlled with associated time, cost and laminate quality issues. This dataset presents the results of 14 evacuation experiments where the vacuum stack was instrumented with an array of 20 pressure transducers and leaks of amplitude comparable to industrial vacuum drop test thresholds were induced at different positions in the vacuum film. Macroscopic quantities were recorded. Experimental results demonstrated that pressure and pressure/time gradient signals can provide robust means for detecting and locating both system leaks and induced leaks, well within the duration of industrially mandated vacuum drop tests for system leaks and within seconds of the appearance of induced leaks. Critically for industrial practice, these capabilities were demonstrated for phases of the vacuum infusion process where the vacuum pump is not operating.