Replication data for: Screening on the wrong margin: retiring network infrastructure under depopulation
Description
This package supports a study of how governments decide which infrastructure to stop maintaining as populations decline. Japan’s Ministry of Land, Infrastructure, Transport and Tourism issued a guide in March 2026 instructing water utilities to examine districts for decentralised supply where the served population is 100 or fewer and the network exceeds 30 metres of pipe per person. The hypothesis is that both criteria are expressed in the wrong units. The guide’s own costed examples show that the decentralised alternatives — hauled water, or a small local source with compact treatment — leave the distribution mains in place and replace only the works upstream of them. The cost a settlement can avoid is therefore transmission, not total network. Because the treatment penalty incurred by going local is close to invariant to settlement size, the switching threshold is a fixed length of transmission main rather than any per-capita quantity. Calibrated on the ministry’s published renewal cost functions, it is 459 to 563 metres. A criterion expressed per person can then be correct at one population only. The analysis tests that implication on 1,724 Japanese water utilities in FY2024, using served population, the length of conveyance and transmission main, total main length, the transmission share of the network, and network intensity in metres per served person. The guide’s criteria match the derived threshold at median network composition, implying a break-even population of 90 to 111 against the stated 100, but diverge sharply at the tails: at the tenth percentile of transmission share the break-even population is 319 to 392, and at the ninetieth it is 39 to 48. Within the 371 utilities the pipe criterion selects, network intensity explains 22 per cent of the variation in transmission per person and 0.6 per cent of the variation in transmission share, so the criterion narrows the field but cannot rank it. The underlying data are administrative accounts of public water utilities, not survey or experimental data, and contain no personal information. They are cross-sectional for FY2024. Transmission share proxies for the cost an alternative could displace; it measures network composition, not the distance from source to settlement, which is not reported. Observations require positive served population, positive total main length and a positive reported distribution main. All sources are published by the Ministry of Land, Infrastructure, Transport and Tourism under the Public Data License 1.0, which permits use subject to source citation. Source: Ministry of Land, Infrastructure, Transport and Tourism website (https://www.mlit.go.jp/mizukokudo/sewerage/mizukokudo_sewerage_tk_000912.html). No source data are redistributed here; the user supplies the public source file, from which the script regenerates the derived panel, the reported statistics and the figure, created by editing the dashboard data.
Files
Steps to reproduce
The analysis combines one public dataset with two public government documents, all published by the Ministry of Land, Infrastructure, Transport and Tourism under the Public Data License 1.0. Nothing was collected by the author; all inputs are administrative records or published engineering estimates. Source: Ministry of Land, Infrastructure, Transport and Tourism website (https://www.mlit.go.jp/mizukokudo/sewerage/mizukokudo_sewerage_tk_000912.html). SOURCE 1 — utility accounts. Statistical table 02 of the local public enterprise water supply dashboard (MLIT, compiled 3 July 2026), FY2024 file. Four items are read per utility: current served population; conveyance main length; transmission main length; distribution main length. Reported in thousands of metres and converted to metres. Transmission share is conveyance plus transmission divided by total length; network intensity is total length divided by served population. Observations require positive served population, positive total length and a positive reported distribution main. The last condition excludes 64 utilities that record conveyance and transmission but no distribution length; this exclusion is material, since retaining them reverses the sign of the correlation between network intensity and transmission share from +0.50 to −0.33. The resulting sample is 1,724 utilities, of which 371 meet the 30 metre per person criterion. SOURCE 2 — case-study costs. Transcribed from the published cost summary tables of the guide for introducing decentralised systems in water supply (MLIT, March 2026), for the two districts costed on a comparable basis. Capital, annual operation and fifteen-year totals are the guide’s own published figures; itemised component rows are a subset and do not sum to the capital total. Figures are thousand yen, constant prices, undiscounted, over the fifteen-year horizon the guide specifies. These are hard-coded at the top of the script with their source tables named, since they come from a PDF rather than a dataset. SOURCE 3 — renewal cost functions. Linear cost functions by pipe diameter from the guide to the calculation of facility renewal costs (MLIT, March 2025), for open-cut daytime renewal of ductile iron with seismic joints, in constant FY2023 prices including overheads and consumption tax. TO REPRODUCE Install Python 3.10 or later with numpy, pandas, matplotlib and scipy. Tested on Python 3.12 with numpy 2.4, pandas 3.0, matplotlib 3.10, scipy 1.17. Download the source archive from the URL above and extract the FY2024 file. Create a folder named gov2 beside replication.py and place the file in it as 2024.csv. It is UTF-8; do not re-save it in another encoding. Run: python replication.py Each computed statistic prints beside the value reported in the article, in parentheses, so any discrepancy is visible on the first run. Runtime is under one minute.