Tensile static tests and thermal expansion coefficients evaluation data of 30 g/m2 and 150 g/m2 cured unidirectional carbon/epoxy prepreg TP402/T700S

Published: 15 March 2024| Version 2 | DOI: 10.17632/s2pp9hbbzf.2
Contributors:
Serafín Sánchez-Carmona,
,
,

Description

In the first folder, tensile static test results of two different unidirectional carbon/epoxy prepregs (30 g/m2 and 150 g/m2) are available. Different configurations are made from each prepreg. 0º unidirectional (UD-0), 90º unidirectional (UD-90), ±45º and 10º off-axis samples are manufactured using 150g/m2 prepreg whereas UD-0 and UD-90 specimens using 30 g/m2 prepreg. Each test file contains the dimensions of the tested sample, the test load, the machine crosshead displacement and the value(s) of the straing gauge(s) used. In the second folder, strain measurements for the evaluation of the thermal expansion coefficients for the 30 g/m2 prepreg are available.

Files

Institutions

Universidad de Sevilla Escuela Tecnica Superior de Ingenieria de Sevilla

Categories

Composite Material, Carbon Fiber, Epoxy-Based Composite, Tensile Testing, Prepreg, Thermal Expansion

Licence