Sensitivity analysis data for Eurocode localized fire model
Description
Dataset consists of SQLite database file samples.db with data required to recreate sensitivity analysis of Eurocode localized fire model. There are two tables with input and output data to be referred to: 1. Table samples consists of 8000 MC samples of parameters for Eurocode localized fire model. 2. Table records stores 7,112,766 data points for Heat Release Rate, heat flux and steel temperature in time derived with the Eurocode localized fire model for parameters sets stored in samples table.
Files
Steps to reproduce
Monte Carlo (MC) analysis was performed on two steel columns, HEB300 and HEB280. Fire parameters were assumed to be stochastic, as for 8 m × 10 m × 5.5 m office building. Distribution parameters for the MC study were taken as follows: Fire load density [MJ/m2], Gumbel, 363.1, 98.6, source: (European Committee for Standardisation, 2002) Fire growth rate [kW/s2], log-norm, -9.15, 1.19, source: (Deguchi et al., 2011) Heat release rate per unit area [kW/m2], Gumbel, 565, 134, source: (Hietaniemi and Mikkola, 2010) Load modifier [−], log-norm, 0, 0.1, source: (Jovanović et al., 2021) Compartment geometry [m], deterministic, 8×10×5.05, — Cross-section dimensions [m], deterministic, nominal, source: (European Committee for Standardisation, 2017)
Institutions
- Szkola Glowna Sluzby Pozarniczej