Angiotensin IV suppresses hippocampal CA1 long-term depression and alters recognition performance after a prolonged retention interval in rats
Description
Source data for a study of how angiotensin IV (Ang IV) affects long-term depression (LTD) at Schaffer collateral-CA1 synapses and object recognition after a prolonged retention interval in adult male Sprague-Dawley rats. The electrophysiological data comprise field EPSP amplitude and slope recorded on an MED64 planar multi-electrode array from acute hippocampal slices, before and for 80 min after low-frequency stimulation, under bath application of Ang IV (0.01-10 microM), the oxytocin receptor antagonist atosiban, the insulin-regulated aminopeptidase inhibitor LVV-H7, recombinant hepatocyte growth factor, a polyclonal anti-c-Met antibody, or normal serum. One slice from one animal contributes one value. The behavioural data come from a prolonged modified novel object recognition paradigm run on six consecutive days, with one intracerebroventricular injection of saline, Ang IV (10 pmol, 100 pmol or 1 nmol), anti-c-Met antibody, or Ang IV plus antibody given 15 min before each session. They comprise per-animal object exploration percentages, discrimination indices and total exploration times, together with an uninjected naive reference group. Every value behind the figures and statistics of the associated article is included, both as the original GraphPad Prism project files and as open-format CSV exports with a README describing each file, column and group.
Files
Steps to reproduce
Animals. Adult male Sprague-Dawley rats, 8 weeks old at the time of recording or behavioural testing. All procedures were approved by the Institutional Animal Care and Use Committee of the National Defense Medical Center (approval no. IACUC-13-326). Electrophysiology. Acute hippocampal slices (250 micrometres) were placed on an MED64 P515A planar multi-electrode probe (8 x 8 array, 50 x 50 micrometre electrodes, 150 micrometre interelectrode distance) and field EPSPs were recorded from the CA1 stratum radiatum. One electrode per slice was analysed and each slice came from a separate animal, so one slice equals one animal equals one value of n. After a 30-min stable baseline, LTD was induced by low-frequency stimulation (40 trains of 45 pulses at 1 Hz, 1800 pulses in total) and fEPSPs were followed for a further 80 min. Drugs were bath-applied from 20 min before LFS and were present throughout. LTD magnitude is the mean response over the final 10 min of the post-LFS recording (70-80 min after LFS), expressed as a percentage of the pre-LFS baseline; this is the value in ephys_summary_70-80min_post-LFS.csv on which every slice statistic in the article was computed. Behaviour. A prolonged modified novel object recognition paradigm run on six consecutive days. Rats received one intracerebroventricular injection (5 microlitres) per day, 15 min before each session. Three objects were used: a familiar object (F), novel object 1 (N1) and novel object 2 (N2). The pair presented on each day was F/F (Day 1), N1/F (Day 2), N1/N1 (Day 3), N2/N1 (Day 4), N2/N2 (Day 5) and N2/F (Day 6), so Day 6 compares a remote familiar object (F, last seen on Day 2) with a more recently encountered one (N2, last seen on Day 5). Exploration of each object was scored and expressed as a percentage of that session's total exploration time. The discrimination index uses a single convention on every session, the object newly introduced or reintroduced into the pair that day being the first term. Acquisition, analysis and software. Field potentials were acquired with Performer (MED64 system, Alpha MED Scientific). All statistics were computed in GraphPad Prism 10.4.1: one-way ANOVA with Dunnett's test against a single control or Tukey's test for all pairwise comparisons, unpaired Student's t-test for two-group comparisons, and paired Student's t-test for within-session object comparisons. Because the multiple-comparison family and the pooled error term differ between analyses, the adjusted p value for the same pair of groups can differ between figures. The two GraphPad Prism project files in this deposit reproduce every figure and test directly; the CSV exports contain the same values in tidy form, and the README describes each file, column and group.
Institutions
- National Defense Medical CenterTaiwan, Taipei