I/O data for laboratory model PT326 Feedback Ltd
Description
Description of this experimental data is also given on the website http://graasp.eu/s/oy04aj Experimental setup is laboratory model PT326 Feedback Ltd. Process trainer (PT326) is used for experiments in open loop. Input and output signals (I/O signals) are saved with sampling time Ts=0.11 [s]. I/O signals have range from 0 to 10 [V]. Input signal controls heater's power and has influence on air heating which flows through the heater and tube. Output signal represents measurement signal of air temperature in the tube of laboratory model PT326. Experimental data consist of 21 sets of experimental results. Each set consists of 3 files, and each file has two column with Input and Output experimental sequences. The sampling time is Ts=0.11 [s]. Environmental conditions are the same for all experiments. Conduction of experimens is going consequently with maximal pause about one minute. Input signal is step: 5+1*h(t-11). Output signal is step response of the system in open loop. The purpose of described experimental protocol is collecting of data for identification of the process model