Induction Motor Vibration and Acoustic Cellular Device (IM-VACD)
Description
The dataset consists of constant and variable speed data collected from 8 different D396 Marathon Electric 3-phase motors. Each motor has different types of faults artificially created by SpectraQuest. Data is collected using three cellphones sensors (accelerometers and a microphone) (the first column is acoustic data, the second, third and fourth columns are accelerometer data [x,y,z axis data]). The labelling of data is as follows {Letter}-{Letter}-{Letter}-{Number}-{Number}: The following values represent the possibilities for the first letter: - A indicates iPhone 13 - B indicates Samsung Galaxy S6 - C indicates Samsung Galaxy A50 The following values represent the possibilities for the second letter: - H indicates healthy - R indicates rotor - S indicates stator - V indicates voltage - B indicates bowed - K indicates broken - F indicates faulty The third letter is represented by the following possible values: - H indicates healthy - U indicates unbalance - M indicates misalignment - W indicates winding - R indicates rotor - A indicates rotor bars - B indicates bearing The combination of both letters indicates the health state of the motor present in the data sample (e.g. H-H = a healthy motor, S-W = a stator winding fault). The first number represents: - 1 is for a constant speed of 15 Hz - 2 is for a constant speed of 20 Hz - 3 is for a constant speed of 25 Hz - 4 is for a constant speed of 30 Hz The second number represents: - 0 for a no load condition - 1 for a loaded condition The duration of data collection was 10 seconds at a sampling frequency of iPhone 13 at 100 Hz, Samsung Galaxy S6 at 200 Hz, and Samsung Galaxy A50 at 490 Hz for accelerometer data. For acoustic data, all phones were collected at 42,000 Hz for a 10-second data duration. Each file contains 420,000 samples. Raw data is provided in the folders as comma separated values files (.csv).
Files
Steps to reproduce
List of Components #, Component Type, Make and Part Name, data column # 1, iPhone 13 [1] 2, Samsung Galaxy S6 [2] 3, Samsung Galaxy A50 [3] 4, Signal conditionner, PCB 482C 4-Channel [4] 5, Data acquisition device, NI USB-6212 [5] 6, Motor, Marathon Electric D396 [6] Selected Sensors: Specification of each sensor that helped in setting up the data acquisition system include: - Accelerometer 1 (model 603C01): the sensitivity rating is 100 mV/g, the frequency range is 10,000 Hz, and the measuring range is ± 490 m/s2, temperature range of +2 to +121 °C with a scale factor of +10 mV/°C [1]. - Accelerometer 2 and 3 (model 623C01): the sensitivity rating is 100 mV/g, the frequency range is 15,000 Hz, and the measuring range is ± 490 m/s2 [2]. - Microphone (model 130F20): the sensitivity is 45 mV/Pa, and the inherent noise is 29 dB [3]. References: [1] "iPhone 13." Accessed: June. 5, 2024. [Online]. Available: https://www.apple.com/ca/shop/buy-iphone/iphone-13 [2] “Samsung Galaxy S6.” Accessed: June. 5, 2024. [Online]. Available: https://www.samsung.com/us/mobile/phones/galaxy-s/samsung-galaxy-s6-32gb-unlocked-black-sapphire-sm-g920tzkaxar/ [3] “Samsung Galaxy A50.” Accessed: June. 5, 2024. [Online]. Available: https://www.samsung.com/us/mobile/galaxy-a50/ [4] “Series 482.” Accessed: September. 20, 2023. [Online]. Available: https://www.pcb.com/sensors-for-test-measurement/electronics/line-powered-multi-channel-signal-conditioners/series-482-4-channel [5] “USB-6212.” Accessed: Nov. 02, 2023. [Online]. Available: https://www.cnrood.com/en/781003-01 [6] “Marathon Electric D396, 3 Hp, 3600 Rpm, 56HC FR, 230/460 Vac, 3 PH, TEFC, C-Face Footed, General Purpose, Standard Efficiency, 56T34F5306.” Accessed: Nov. 10, 2023. [Online]. Available: https://www.industrialmotors.com/marathon-electric-d396-3-hp-3600-rpm-56hc-fr-230-460-vac-3-ph-tefc-c-face-footed-general-purpose-standard-efficiency-56t34f5306.html