Filter Results
46 results
- Data for: Fiber Bragg grating biaxial tilt sensor using one optical fiberThis supplementary file is consisted of 3 excel spreadsheets, and gives the detailed theoretical and experimental results of an Fiber Bragg grating (FBG) biaxial tilt sensor. FBG bialxial tilt sensors used to use two optical fibers and four FBGs to measure inclination in two perpendicular directions, whereas here we have demonstrated one using one optical fiber and two FBGs. The inclination along the direction of the fiber (axial direction) can be distinguished by the difference of the resonant wavelengths of the two FBGs, and the inclination in the transverse direction distinguished by the average of the resonant wavelengths of the two FBG. In the experiments, from -50° to 50° in the axial direction, the difference changed linearly with inclination, R2=0.998, and the sensitivity was 1.1pm/°; from 20° to 70° in the transverse direction, the average changed linearly with inclination, R2=0.902, and the sensitivity was 4.5pm/°.
- Dataset
- Data for: Optimization of five-parameter BRDF model based on Hybrid GA-PSO algorithmThere are 501 rows and 36 columns; each represents a wavelength; 1-501 rows correspond to the wavelength of 400-900 nm; each column corresponds to a different receiving angle. When the incident angle is different, the receiving angle of each column is different. The definition of incident angle: the angle between incident angle and plane normal. The definition of receiving angle definition: the angle between receiving angle and plane normal, if receiving angle and incident angle are on the same side of normal, then receiving angle is negative, and receiving angle and incident angle are on both sides of normal.
- Dataset
- Data for: Design of a histopathology image segmentation algorithm for CAD of cancerThese are four sample images of ADL dataset mages with segmentation ground truth. Other files will be provided as per the request.
- Dataset
- Data for: The application of Confocal depth-resolved micro-X-ray absorption spectroscopy to study colorant copper in ancient lead-si`lica glassy system at the Beijing Synchrotron Radiation Facilitythis is orignal data of expertimtenal
- Dataset
- Data for: Removable camera based 2D digital image correlation for planar slender area quasi-static deformation measurementImage & Matlab codes
- Dataset
- Data for: A Novel Percentage Split Distribution Method for Image SegmentationThe images are used for analyzing the performance of the propsed method for image segmentation
- Dataset
- Data for: Nonlinear signal processing in a chalcogenide plasmonic nanoresonatorWe have numerically studied the quasi pulse evaluation in a nonlinear metal-dielectric-metal (MDM) plasmonic nanoresonator at telecom wavelength. In this system a MDM waveguide, vertically coupled to stub filled with nonlinear chalcogenide glasses to make a nonlinear plasmonic nanoresonator (NPNR). NPNR shows two kinds of optical bistability i.e. S-type and Z-type. The effect of S-type and Z-type bistability on the Gaussian input pulse is studied numerically and showed that the output pulses are square pulse for S-type and nearly dark soliton shape for Z-type pulse if the peak input intensity larger than critical intensity. The output shape of pulse is strongly depending on the input peak power of pulse so such signal processing refers to all optical self-signal processing.
- Dataset
- Data for: Multi-parameter sensor based on the fiber Bragg grating combined with triangular-lattice four-core fiberThese data are the experimental data from Fig. 3 to Fig. 6.
- Dataset
- Data for: Visually meaningful encryption for color images by using Qi hyper-chaotic system and singular value decomposition in YCbCr color spacesource code of visually meaningful encryption for color images by using Qi hyper-chaotic system and singular value decomposition in YCbCr color space
- Dataset
- Data for: Image plane interference co-phasing technology for synthetic digital holographyThe uploaded data are 2x2 arrayed dugital holograms, single hologram rebuilt image, and the 4apertures co-phasing imaging. The digital holograms is recorded with 532nm wavelength laser, 3856x2754 pixels CMOS. The pixel pitch is 1.67um, the 4 holograms are 2 times zero padded and not according to the distance among the CMOS sensors , the pitch among them is about 2cm but not considered .
- Dataset
1